Property Inspection Report
|
||||||||
Final Analysis Property Inspections 1385 Fordham Dr. Ste. 105, Virginia Beach VA 23464 |
||||||||
Prepared exclusively for removed for privacy |
||||||||
xxxx S Palm Ave Virginia Beach VA 23452 |
||||||||
|
||||||||
Report ID:
xxxx090816 |
||||||||
|
||||||||
Inspection Date:
9/8/2016 |
||||||||
Inspector: |
||||||||
757.495.2300 |
||||||||
Date: 9/8/2016 | Time: | Report ID: xxxxxx090816 |
Property: xxxx S Palm Ave Virginia Beach VA 23452 |
Customer: removed for privacy |
Real Estate Professional: Melissa Ly Coldwell banker |
Type of Inspection: Home Buyers inspection | Inspectors: Reuben Autery- DPOR 3380000742 | Inspection Procedures: American Society of Home Inspectors, Standards of practice |
Inspection Restrictions/limitations: None | General inspection accessibility: Vaccant, Unoccupied, Typical accessible | All Utility services are on?: Yes |
In Attendance: Buyer, Buyers Agent | Type of building: Single Family (2 story) | Square Feet of conditioned space: 1,800 SF |
Age of building (year built): 2016 - New Construction | # of Bedrooms: 3 Bedrooms | # of Bathrooms: 2.5 bathrooms |
Temperature during inspection: 87 degrees | Weather: Cloudy | Ground/Soil surface condition: Wet |
Garage: 1 car, Attached |
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it is satisfactory and appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit does not exists in this home or building.
Information & Disclosures (ID) = Indicated with an ORANGE flag and text. This is Important information you should know about this house or building including, disclosures, alerts, advisories and warnings about typical conditions or circumstances for this home. Not necessarily something abnormal or unusual or in need of action, but none the less critical information that may pose significant concern for health risk, environmental safety or additional cost. These "orange flag" items will also be separately listed in the Information and Disclosure summary page of this report.
Repair or Replace (RR) = Indicated with a RED Flag and text. Corrective action recommended. These items, systems, components or unit is not functioning as intended, defective, broken or otherwise needs further inspection and evaluation by a qualified contractor. Items, components or units that should be repaired, replaced or corrected or otherwise represent significant, unusual, abnormal cost or safety concerns. These "red flag" items will also be separately listed in the DEFECT summary page of this report.
Inspection standards of practice: This inspection was completed in compliance with the professional standards of practice set forth by the American Society of Home inspectors (ASHI) and VA Dept. of Professional Occupation and Regulation (DPOR) for Home Inspectors. These standards and regulations describe the scope, procedures and limitations of a standard home inspection and are provided for your review. Additionally the ASHI standards of practice are included in the appropriate header section of each corresponding system of the report.
Purpose and Objective: This inspection is not technically exhaustive and can not be conclusive of every detail. The primary objective of this building inspection is to identify and report MATERIAL DEFECTS. Material Defects are defined as a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at or beyond the end of its normal useful life is not, in itself, a material defect. Normal wear and tear, maintenance typical defects or deficiencies are not defined as material defects. That is not to say that the home inspector will not report smaller defects such as cracked glass, broken outlets or leaky faucet washers but this is not the primary objective of an inspection. The home inspection is a first look attempt at ascertaining the general condition of a property. While it is the purpose of this inspection to discover and disclose those major items and concerns that may have an adverse impact on the value of this property and the health and safety of it's occupants, it is not an exhaustive list of defects or discrepancies and it certainly should not be used as a punch list of repairs. Repair list and cost estimates should be obtained from contractors. It is important to know that home inspectors are general practitioners with a limited amount of time and capabilities and are primarily focused on major issues in the home. Outside of normal testing and observation, Inspectors do not engage in troubleshooting or diagnostics and can not offer repair advice. Home inspections are limited to visual observations only and does not include technically exhaustive or invasive analysis. However, this report attempts to identify and recommend conditions that should have further evaluation by experts prior to closing or taking ownership.
Typically found on any home and included in any inspection report will be smaller issues, discrepancies, observations and suggestions. These may not be considered serious or significant problems but common to find on all homes and is mostly provided as courtesy in an attempt to give you a more comprehensive understanding of the home. These smaller, typical or common discrepancies are not intended to be all inclusive.
It is the objective of the inspection and report to provide you the means by which you can progress in an informed manner thereby protecting yourself as much as possible before taking ownership of a property. This may mean obtaining further evaluation and repairs by an expert, purchase price adjustments, escrow of funds for repair, or withdrawing from a buyers purchase agreement altogether. If you are subject to an inspection contingency removal purchase addendum your conditions and disposition of removing that contingency should be clearly stated with details of expected outcomes. Furthermore, it should also be stated that any dispositions agreed to should be subjective to your re-inspection and final acceptance of satisfactory completion prior to closing of escrow.
Repairs - No matter how big or small, All repairs, corrections or replacements should be requested to be completed by licensed, qualified professionals with copies of their credentials, licensing, labor and product warranties and receipts of work. It is not recommend that you ask the seller to make the repairs unless they are qualified in the trades and you feel confident that they'll do a good quality job. It should be expected and required that all work be accompanied by any required city permits and inspections. Mostly all work except minor repairs require city permits and inspections. Finally, all repairs should be subject to your re-inspection, satisfaction and approval a couple days before closing. If you are submitting a Property Inspection Contingency Removal Addendum with list of requested repairs (PICRA), you should consider adding the above verbiage to your PICRA because at that point you will be agreeing to buy the house subject to seller repairs and might need assurance they are done correctly.
Reinspection - Due to liability restrictions, reinspections are not the policy of Final Analysis home inspections. All repairs or corrections should be completed by qualified, licensed professional in their trade and should be accompanied by permits, work orders, receipts and warranties. If you feel a reinspection is necessary we can provide on a case by case basis and subject to schedule availability. The property inspection contingency removal addendum (PICRA) should be provided to us when the re-inspection is requested. All re-inspections are subject to a minimum fee of $225 and will be accompanied by an updated report.
NOTICE OF URGENCY: If you are buying this property, any discrepancies, concerns or issues revealed in this report should be resolved to your satisfaction before close of escrow and/or taking possession.
NOTICE - A Termite and moisture inspection was not ordered or completed during this inspection by Final Analysis Property inspections LLC. These are the specific inspections and reports required by some financial institutions to underwrite a mortgage. Termite and Moisture inspections look for and report on the presence of wood damaging organisms. These inspections are typically performed by home inspections company's or pest control companies. It is strongly recommended that you have this completed or have the seller provide termite and moisture clearance documents from a qualified company before taking ownership of the property. Additionally you should have annual inspections for the presence of wood damaging organisms.
Not for 3rd party use - The inspection and report are performed and prepared only for the sole, confidential and exclusive use and possession of the named client(s). Final Analysis Property Inspections accepts no responsibility for use or misrepresentation of this report by third parties who "rely" on the report information but have not directly retained our inspection services and council and are not named in the inspection agreement.
Overview: A thorough home inspection was completed at the subject property in
accordance with the American Society Home Inspections (ASHI) standards. The
inspection reveals that this dwelling is new construction and has no wear and tear.
Its structure and systems are generally sound and well built. All observations made
and items reported here should be carefully reviewed and considered for correction
where needed as they are specific to this home and can have a significant impact on
it's condition, safety and value.
This home is new construction. Please review this report closely to determine if any
item or component was not inspected due to incomplete work or no utilities. It is
common that a new home can need painting or caulking again within the first 5 years
due to normal shrinkage and new material. Settlement cracks found in homes usually
occur within the first three years. Most builders give a one year warranty on materials
and labor. For this reason, please consider another inspection within one year to get
the most out of your warranty with your builder.
The inspector is NOT required to inspect: A. antennae. B. interiors of vent systems, flues, and chimneys that are not readily accessible. C. other installed accessories.
GENERAL ROOF CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Roof service life remaining::
80% - 100% (Very Good - No concerns) |
Roof covering material:
Architectural style asphalt shingles |
Methods used to inspect the roof:
Remote camera |
Roof drainage system:
No roof drainage systems installed |
Attic Ventilation:
Ridge vents Soffit intake vents installed Passive Attic ventilation is satisfactory |
1.0 |
ROOF MATERIALS
Comments and observations: Inspected |
Maintenance - Observed the tree limbs that are in contact with roof (and siding) or hanging near roof which can cause damage.(Item 1-2) These limbs should be trimmed away so
they are not overhanging the roof or touching the structure.
1.0 (Item 1)
1.0 (Item 2)
|
1.1 |
FLASHINGS
Comments and observations: Inspected |
Disclosure - Roof flashings by design are mostly concealed and therefore inspection is limited to visible areas only followed by examinations and testing of the interiors where leaks are suspected. Some leaks can not be detected and will only show during certain weather conditions. |
1.2 |
SKYLIGHTS, CHIMNEYS and Other ROOF PENETRATIONS
Comments and observations: Inspected |
1.3 |
ROOF DRAINAGE SYSTEMS
Comments and observations: Inspected |
1.4 |
ATTIC VENTILATION
Comments and observations: Inspected |
General Statement - Attic ventilation plays an important role in reducing the heat loads in your attic, dissipating trapped moisture and contributing to the overall health of your
attic/roof system. A poorly ventilated attic can reduce HVAC performance, shorten shingle life, and will promote rot of wood materials if moisture can't escape. Poor eave/soffit vents
are the # reason for poor attic ventilation. Typically newer homes are better ventilated but older homes 20+ years, should be reviewed for improvement. It is important to remember that
you need balanced intake vents along with outlet vents for good air flow. Installing just a power fan may not accomplish this. See more ventilation tips here
Attic is ventilated satisfactorily. |
The inspector is NOT required to inspect: A. screening, shutters, awnings, and similar seasonal accessories. B. fences, boundary walls, and similar structures. C. geological and soil conditions. D. recreational facilities. E. outbuildings other than garages and carports. F. seawalls, break-walls, and docks. G. erosion control and earth stabilization measures.
GENERAL EXTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Siding material:
Vinyl |
Trim materials:
Aluminum coil stock Vinyl |
Exterior Entry Doors:
Steel Sliding vinyl |
Appurtenance:
Balcony Patio |
Driveway:
Concrete |
Evidence of water intrusion at exterior walls windows doors:
No |
2.0 |
Siding, Trim, Eaves, Flashings, Exterior finishes
Comments and observations: Inspected |
(1) Defect - Trim is loose/damaged at the left-rear corner which can allow water intrusion.(Item 1) Recommend repairs.
2.0 (Item 1)
|
|
(2) Defect - The trim at both sides of the garage door are not fully wrapped around the wood framing and wood is exposed which will result in damage and rot over time.(Item 2-3)
Recommend repairs.
2.0 (Item 2)
2.0 (Item 3)
|
|
(3) Deficiency - A small metal rod is protruding from the foundation block near the front door entrance. (Item 4) Recommend removal of protrusion.
2.0 (Item 4)
|
2.1 |
Doors (exterior)
Comments and observations: Inspected |
(1) Defect - The wooden threshold supports need a paint/stain covering to help prevent rot over time.(Item 1-3) Also, the nail heads attaching the thresholds are protruding out slightly in
some locations. Recommend repairs.
2.1 (Item 1)
2.1 (Item 2)
2.1 (Item 3)
|
|
(2) Defect - Sliding door screen is missing. (Item 4) Recommend installation.
2.1 (Item 4)
|
2.2 |
Windows (exterior)
Comments and observations: Inspected |
Defect - All the windows are missing their screens.(Item 1-7) Screens were observed in the closet in the garage. (Item 8) Recommend installing screens.
2.2 (Item 1)
2.2 (Item 2)
2.2 (Item 3)
2.2 (Item 4)
2.2 (Item 5)
2.2 (Item 6)
2.2 (Item 7)
2.2 (Item 8)
|
2.3 |
Decks, Balconies, Stoops, Steps, Porches, Patio/Sun rooms, Railings
Comments and observations: Inspected |
2.4 |
Vegetation, Grading, Drainage, Driveways, Walkways, Retaining walls (With respect to their effect on the condition of the building)
Comments and observations: Inspected |
(1) Deficiency - Observed standing water at the left side and the rear of the home. (Item 1-2) The left side (as viewed from front of house) and rear lot has grade depressions or is
otherwise poorly graded in a way that is not conducive to good water shed and positive drainage. generally speaking, the lot should be crowned around the dwelling and have a
positive slope that drains water away from structure and to edges of property and eventually into the storm drains. Lots with poor drainage can cause a wide range of
problems with the structure if the water is pooling around the foundation or entering the crawlspace. Additionally poor drainage or standing water may cause a muddy lot and fungal
growth on the yard. It is recommended that this condition be considered for improvement.
2.4 (Item 1)
2.4 (Item 2)
|
|
(2) Defect - The driveway is not complete.(Item 3) Reportedly, one section was removed to perform repairs on the main drain plumbing system as required by the City of Virginia Beach.
This section of driveway needs to be re-installed.
Defect - A section of the driveway (adjacent to the removed section) is damaged and needs repairs. (Item 4) 2.4 (Item 3)
2.4 (Item 4)
|
|
(3) General Information - Positive grading and drainage are essential to the welfare of a property, and are usually the primary concern of architects and builders. Moisture can deteriorate most surfaces, cause soil movement and erosion, and undermine the structures foundation. The ideal site will be graded to conduct water away from a building. In fact, the ideal building will be surrounded by hard surfaces that slope way from the exterior walls, the interior floors will be several inches higher than the exterior grade, and the building will have gutters and downspouts and a system of drainage designed to prevent any moisture from threatening the foundation or the living space. Unfortunately, many properties do not meet this ideal, conditions on most can generally be improved, and all need to be monitored and maintained to prevent damage. Also, inspectors cannot see inside area drains and do not water-test them, but they can become blocked by debris, occluded by silt, and damaged by movement. Therefore, buyers should question sellers about the functionality of any such system, have it serviced by a specialist, or assume the risk of having a system that does not function well and the damage that might result |
2.5 |
Garage, Garage door, opener safety reverse (if applicable)
Comments and observations: Inspected |
(1) Observed - According to the buyer, the seller is contracted to install a garage door opener. (Item 1) As of the day of inspection, opener not installed and could not be inspected.
2.5 (Item 1)
|
|
(2) Observation - The depth of the garage door (when closed) to the bollard in front of the water heater is approximately 18'. The 18' depth of the garage may make it difficult to park some large cars in the garage and it may be difficult to walk around the front or rear of many regular sized cars. |
This inspection does not test for or report on the presence of MOLD or other indoor air quality issues or hazards.
GENERAL INTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Ceiling construction materials:
Drywall, Sheet rock, Gypsum |
Wall constructuion material:
Gypsum board (typical) |
Floor Covering(s):
Multiple styles Carpet Hardwood T&G Vinyl or Linoleum |
Window Types:
Vinyl or Plastic Single-hung Thermal/Insulated |
Interior Doors / types / styles:
Hollow core Raised panel |
Cabinetry:
Wood |
Countertop:
Granite |
3.0 |
CEILINGS
Comments and observations: Inspected |
3.1 |
WALLS
Comments and observations: Inspected |
3.2 |
FLOORS
Comments and observations: Inspected |
(1) Defect - Floor scratches were noted in front of the dish washer and the stove. (Item 1-3) The scratches appear to have been caused during the installation process. Recommend
repairs by qualified flooring specialist.
3.2 (Item 1)
3.2 (Item 2)
3.2 (Item 3)
|
|
(2) Defect -The threshold transitions at both bathrooms are not fully installed and are trip hazards. (Item 4-7) Recommend correct installation.
3.2 (Item 4)
3.2 (Item 5)
3.2 (Item 6)
3.2 (Item 7)
|
|
(3) Defect - The wooden subfloor under the carpet is making squeaking noises when walked upon and need to be more securely attached (landing area and middle bedroom door
areas).(Item 8-11)
3.2 (Item 8)
3.2 (Item 9)
3.2 (Item 10)
3.2 (Item 11)
|
|
(4) Defect - The bamboo wood flooring is buckling slightly in the corner of the living room.(Item 12) Recommend evaluation and repairs by a qualified flooring specialist.
3.2 (Item 12)
|
3.3 |
STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments and observations: Inspected |
3.4 |
COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments and observations: Inspected |
3.5 |
DOORS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
Defect - The balcony door dead bolt lock is not properly aligned with the frame and the lock will not engage. (Item 1-2) Recommend repairs.
3.5 (Item 1)
3.5 (Item 2)
|
3.6 |
WINDOWS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
GENERAL STRUCTURAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Attic access:
Ceiling scuttle hole |
Method used to observe attic:
Walked |
Crawl space access point:
N/A slab foundation |
Method used to observe Crawlspace:
No crawlspace |
Is there significant structural faiulre/damage/distress was observed/suspected:
NO |
Was there evidence of Termits- Powder post beetles or wood destroying fungus- mold- mildew- spores:
NO |
Was there evidence of Harmful Moisture / Water Conditions at foundation/crawlspace:
None visibly detected |
Was there evidence of Harmful Moisture Conditions in Attic:
No |
Crawlspace ventilation:
N/A slab foundation |
Foundation type:
Concrete slab |
Floor Structure:
Concrete slab on grade |
Wall Structure:
Concealed, Not visible, Not determined |
Columns or Piers:
N/A Concrete slab |
Ceiling Structure:
Bottoms of roof trusses (2"x4") |
Roof Structure:
Engineered wood trusses |
Roof-Type:
Gable |
4.0 |
FOUNDATIONS, SLABS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. Fungus or wood destroying insects)
Comments and observations: Inspected |
4.1 |
VAPOR RETARDERS (Crawl pace)
Comments and observations: Not Present |
4.2 |
STRUCTURAL FRAMING walls, floors, ceilings (where visible)
Comments and observations: Inspected |
No structural framing distress or failure was visibly detected. |
4.3 |
STRUCTURAL MASONRY, COLUMNS, PIERS, CONCRETE SLAB
Comments and observations: Inspected |
Deficiency - Observed cracking of one masonry block in the foundation wall. (Item 1) The cracking appears to be largely on the exterior outer layer of the block and no structural
compromise was observed. The garage side of the block was observed and no cracking issues were noted. This type of defect is usually caused by an inherently weak block or from
exterior damage rather than a settlement issue. Recommend monitoring the area in the future to determine if any further action is necessary such as permanent repairs to be
determined by a qualified masonry contractor or foundation specialist. Recommend considering covering the area with parging which would cosmetically improve the block and could
help keep the block from fracturing more. (Parging is the thin outer coating of concrete often applied on the exterior of masonry block foundations. It is cosmetic in nature and not a
structural support item.)
4.3 (Item 1)
|
4.4 |
ROOF STRUCTURE AND ATTIC
Comments and observations: Inspected |
4.5 |
CRAWL SPACE VENTILATION (if applicable)
Comments and observations: Not Present |
4.6 |
RETAINER WALLS
Comments and observations: Not Present |
GENERAL PLUMBING SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Water heater service life remaining:
80% - 100% (Very Good - No concerns) |
Probability of plumbing leaks:
Low |
Domestic Potable Water Source (not yard irrigation):
Public (municiple) |
Plumbing waste system:
City sewage |
Water Supply pipe (from street meter):
Not visible |
Water Distribution pipes (inside structure - visible areas only):
PEX (Cross-linked polyethylene) |
Plumbing Waste / Drain pipe materials:
PVC (Polyvinyl Chloride) |
Domestic hot water source:
Electric storage tank Located in garage |
Water Heater Capacity:
50 Gallon (2-3 people) |
Hot water temperature:
110-120 deg F. (low) |
Gas piping on premises:
Natural Gas |
Main water shut off location:
Primary valve is at the municipal water meter location Secondary water shut off is in the garage |
Main fuel shut off:
At the gas meter at the rear exterior of house |
5.0 |
PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments and observations: Inspected |
5.1 |
PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments and observations: Inspected |
Defect - Backflow preventer device is either inoperable or missing from hose bib.(Item 1-2) Backflow preventers are required to prevent bacterial cross connect and contamination of
municipal water supplies. Recommend professional corrections be completed by a qualified plumbing contractor.
5.1 (Item 1)
5.1 (Item 2)
|
5.2 |
HOT WATER SYSTEMS
Comments and observations: Inspected |
(1) Deficiency - The hot water temperature is abnormally low (Item 1) and may indicate a problem with the water heater or the temperature setting is too low. The water temperature
should be between 120 and 130 deg F. Recommend further evaluation and correct as needed.
5.2 (Item 1)
|
|
(2) General safety information about hot water temperatures - Hot water systems can be a scald hazard and a source of disease. Water temperatures higher than 130 deg F. can
be a scald hazard. Water temperatures less than 120 deg. F. is considered ideal for the growth of harmful bacteria inside the tank–such as Legionella. Monitor your hot water
temperatures for safety.
Information sources: http://EPA/Legionella: Drinking Water Health Advisory |
5.3 |
FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)
Comments and observations: Inspected |
5.4 |
MAIN FUEL SHUT OFF (Describe Location)
Comments and observations: Inspected |
FYI - The main fuel shut off is at the gas meter. |
5.5 |
SUMP PUMP, LIFT PUMPS, GRINDERS
Comments and observations: Not Present |
The Inspectors shall describe: 1. amperage rating of the service. 2. location of main disconnect(s) and subpanels. 3. Thee presence or absence of smoke alarms and carbon monoxide alarms. 4. the predominant branch circuit wiring method.
The inspector is NOT required to inspect: 1. remote control devices. 2. or test smoke and carbon monoxide alarms, security systems , and other signaling and warning devices. 3. low voltage wiring systems and components. 4. Ancillary wiring systems and components not a part of the primary electrical power distribution system. 5. Solar, geothermal, wind, and other renewable energy systems. B. measure amperage, voltage, and impedance. C. Determine the age and type of smoke alarms and carbon monoxide alarms.
GENERAL ELECTRICAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Electrical inspection limitations:
None, Inspected in accordance with ASHI standards of practice. |
Electrical Service Cable (from utility pole or transformer):
Below ground Aluminum 220 volts 4/0 cable |
Location of MAIN electric service panel(s):
garage |
Electric service and panel(s):
200 AMP Main breaker Circuit breakers |
Branch circuit wiring/distribution for 15 and 20 AMP lighting and outlets:
Solid Copper Romex - NM plastic (normal - typical) Grounded (3 prong outlets) |
SMOKE DETECTORS:
Yes |
CARBON MONOXIDE DETECTORS:
No CO detectors installed |
6.0 |
SERVICE ENTRANCE CONDUCTORS
Comments and observations: Inspected |
6.1 |
SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments and observations: Inspected |
6.2 |
BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments and observations: Inspected |
6.3 |
CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments and observations: Inspected |
6.4 |
POLARITY AND GROUNDING OF ELECTRIC RECEPTACLES
Comments and observations: Inspected |
6.5 |
OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
6.6 |
OPERATION OF AFCI (ARCH FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
Information/Disclosure - Non Arch Fault Circuit Interrupts , SAFETY - This home was built before AFCI technology and therefore is missing some or all AFCI protection in
bedrooms. AFCI's protect against shorts, sparking and fires.. Recommend consider upgrading to AFCI protection.
“Older homes are statistically more vulnerable to electrical fires. Extra protection for older homes is provided by the gradual replacement, over time, of non-AFCI-protected receptacles with new AFCI-protected ones.” The NEC AFCI's prevent fires. Click here for more information on AFCI's |
6.7 |
SMOKE and CARBON MONOXIDE DETECTORS
Comments and observations: Inspected |
Safety advisory - Install modern smoke and Carbon monoxide detectors where needed for and test monthly. Older detectors should be updated. Change the batteries annually. These
devices save lives. Read more about smoke detectors at US consumer safety products commission. and at National Fire Protection Association.
The two most commonly recognized smoke detection technologies are ionization smoke detection and photoelectric smoke detection. Ionization smoke detection is generally more responsive to flaming fires. How they work: Ionization-type smoke alarms have a small amount of radioactive material between two electrically charged plates, which ionizes the air and causes current to flow between the plates. When smoke enters the chamber, it disrupts the flow of ions, thus reducing the flow of current and activating the alarm. Photoelectric smoke detection is generally more responsive to fires that begin with a long period of smoldering (called “smoldering fires”). |
AC - The inspector shall: A. open readily openable access panels. B. inspect: 1. central and permanently installed cooling equipment. 2. distribution systems. C. describe: 1. energy source(s). 2. cooling systems.9.2 The inspector is NOT required to: A. inspect electric air cleaning and sanitizing devices. B. determine cooling supply adequacy and distribution balance. C. inspect cooling units that are not permanently installed or that are installed in windows. D. inspect cooling systems using ground-source, water-source, solar, and renewable energy technologies.
FIREPLACES AND FUEL-BURNING APPLIANCES - The inspector shall: A. inspect: 1. fuel-burning fireplaces, stoves, and fireplace inserts. 2. fuel-burning accessories installed in fireplaces. 3. chimneys and vent systems.B. describe systems and components listed in 12.1.A.1 and .2. The inspector is NOT required to: A. inspect: 1. interiors of vent systems, flues, and chimneys that are not readily accessible. 2. fire screens and doors. 3. seals and gaskets. 4. automatic fuel feed devices. 5. mantles and fireplace surrounds. 6. combustion air components and to determine their adequacy. 7. heat distribution assists (gravity fed and fan assisted). 8. fuel-burning fireplaces and appliances located outside the inspected structures. B. determine draft characteristics. C. move fireplace inserts and stoves or firebox contents.
GENERAL HEAT SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
HEAT SYSTEM - SERVICE LIFE REMAINING::
80% - 100% (Very Good - No concerns) |
Heat Type:
Heat Pump Forced Air (also provides cool air for AC) |
Heat system(s) performance:
Satisfactory |
Heat system(s) capacity:
Satisfactory |
Heat System Energy Source:
Electric |
Number of Central Heat Systems:
One |
GENERAL AC/ HP SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
HEAT PUMP / AC - SERVICE LIFE REMAINING::
80% - 100% (Very Good - No concerns) |
Cooling Equipment Type:
Heat Pump Forced Air (also provides warm air, Heat) |
AC/Heat Pump system(s) performance:
Satisfactory |
AC/Heat Pump system(s) capacity:
Satisfactory |
Number of Central AC / HP systems:
One |
Number of conditioned zones in the house/building:
1 |
Ductwork:
Combination insulated flex duct Insulated Metal |
Filter Type:
Disposable |
Types of Fireplaces:
Factory pre-fab metal Masonry Electric heater, simulated fireplace |
Number of operable fireplaces:
One |
7.0 |
HEATING, FURNACE EQUIPMENT
Comments and observations: Inspected |
7.1 |
PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM
Comments and observations: Inspected |
7.2 |
AC COOLING, HEAT PUMP AND AIR HANDLER EQUIPMENT
Comments and observations: Inspected |
(1) Defect - The condenser cabinet is flush with the surrounding grade in some areas and is in contact with wet grade and is subject to rust damage. (Item 1-3) The condenser pad
appears to have been installed sunken into the grade rather than flush with the grade which would provide a proper clearance from the soil for the unit. Recommend professional repairs
be completed by a qualified HVAC contractor.
7.2 (Item 1)
7.2 (Item 2)
7.2 (Item 3)
|
|
(2) Deficiency - The condensation drain line is uninsulated and condensation is forming and dripping into both the drain pan and the attic area most near the drain pan. (Item 4) Over
time, dripping condensation will cause rust to the drain pan and damage to the attic area. Recommend insulating drain line to prevent condensation.
7.2 (Item 4)
|
|
(3) Deficiency - Blown insulation was observed in the condensation drain pan of the air handler.(Item 5) Insulation can clog the drain line and prevent the drain pan from functioning as
designed. Recommend removal of all insulation/debris from the drain pan.
7.2 (Item 5)
|
|
(4) Defect - No automatic condensate shut off switch was observed on the drain line or in the drain pan. (Item 6) Recommend evaluation and repairs by qualified HVAC contractor.
7.2 (Item 6)
|
|
(5) Heat Pump Equipment performance - This home is heated and cooled with a heat pump system. It is the same system and equipment that provides warm air in the winter and cool
air in the summer. When the outside temperature is below 60 deg. F. the system is tested in "heat" mode, When the outside temperature is above 60 deg.F. it is tested in the "cool"
mode. Heat pumps can only be tested in Heat or Cool but not both.
DUE to the temperature on the day of inspection, the heat pump was only tested in AC mode. The ambient air test was performed by using thermometers on the air handler of Air conditioner to determine if the difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air temperature on your system read 56.9 degrees(Item 8) , and the return air temperature was 73.1 degrees. (Item 7) This indicates an 16.2 degree difference and indicates satisfactory performance and the system is functioning as designed. Most heat pump systems contain auxiliary (emergency, back-up) heat, typically electric coils but can be gas or oil. This is always tested winter or summer for response. However, some electronic thermostats when in "cool" mode will not allow manual switching to axillary heat, in which case it can not be tested. Test of Emergency Heat Upstairs unit. - The emergency heat mode was tested and showed proper function. (Item 9) 7.2 (Item 7)
7.2 (Item 8)
7.2 (Item 9)
|
7.3 |
PRESENCE OF INSTALLED AC/HP SOURCE AIR IN EACH ROOM
Comments and observations: Inspected |
7.4 |
NORMAL OPERATING CONTROLS
Comments and observations: Inspected |
7.5 |
DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments and observations: Inspected |
7.6 |
CHIMNEYS, FLUES AND VENTS (for fireplaces, water heaters or heat systems)
Comments and observations: Inspected |
7.7 |
SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove)
Comments and observations: Not Present |
7.8 |
GAS/LP FIRELOGS AND FIREPLACES
Comments and observations: Inspected |
Observed - The electric fireplace was functioning on the day of inspection. (Item 1)
7.8 (Item 1)
|
GENERAL INSULATION CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Attic insulation:
Loose or blown in cellulose good Extra Info : neesd |
Wall insulation:
concealed, not visible, not inspected |
Floor System Insulation:
N/A slab construction |
Bathroom steam vents:
Fan with light |
Dryer Power Source:
220 Electric |
Dryer duct (built in):
Metal |
8.0 |
INSULATION IN ATTIC / CEILING
Comments and observations: Inspected |
(1) Defect - Attic insulation is less than R-38 in most locations. (Item 1-8) Recommend thickness be increased to R-38.
8.0 (Item 1)
8.0 (Item 2)
8.0 (Item 3)
8.0 (Item 4)
8.0 (Item 5)
8.0 (Item 6)
8.0 (Item 7)
8.0 (Item 8)
|
|
(2) Defect - The seal strip for the scuttle hole is not fully attached and is coming loose in multiple locations. (Item 9) Recommend installation.
8.0 (Item 9)
|
|
(3) Deficiency - The scuttle hole door foam insulation is not permanently installed on the door hatch and falls off during normal operation of the scuttle hole door. (Item 10) Also, the
insulation R-value appear inferior. Ideally, the attic scuttle hatch should have a similar R-value to the surrounding attic space.
8.0 (Item 10)
|
8.1 |
WALL INSULATION (if visible)
Comments and observations: Inspected |
8.2 |
INSULATION UNDER FLOOR SYSTEM
Comments and observations: Not Present |
8.3 |
VENTING SYSTEMS (Kitchens, baths and laundry)
Comments and observations: Inspected |
SAFETY ADVISORY- Dryer ducts should be cleaned and inspected annually for proper performance. Dryer ducts are susceptible to clogging and blockage due to lint and moisture
build up. Restricted dryer vents will not only reduce drying efficiency, but worse they can overheat and cause fires.
If your dryer used a vinyl or foil flex duct connector you should dispose of it and replace with flexible aluminum duct. Aluminum duct is the most efficient type, safest type to reduce fire hazards and the only type recommended by dryer manufactures and by most municipal building codes. Dryer vent installation guidelines See more about dryer duct safety here. |
GENERAL APPLIANCE CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
GARBAGE DISPOSAL:
Functional Good condition |
DISHWASHER:
Functional Good condition |
RANGE/OVEN/STOVE/COOK TOP:
Functional Good condition |
MICROWAVE OVEN (built in):
Functional Good condition |
STOVE EXHAUST / RANGE HOOD:
Functional Good condition |
9.0 |
DISHWASHER
Comments and observations: Inspected |
Deficiency - The dishwasher feet appear propped upon narrow wedges and the wedges appear to have play. (Item 1-2) Although the unit is attached inside the cabinet space, the
constant opening & shutting of the door (and the weight of the door) could cause sufficient movement that the wedges could wiggle free and the unit would not be correctly supported.
Recommend installing wider wedges with no play.
9.0 (Item 1)
9.0 (Item 2)
|
9.1 |
RANGES/OVENS/COOKTOPS
Comments and observations: Inspected |
9.2 |
RANGE HOOD
Comments and observations: Inspected |
9.3 |
GARBAGE DISPOSAL UNIT
Comments and observations: Inspected |
9.4 |
MICROWAVE COOKING EQUIPMENT
Comments and observations: Inspected |