Property Inspection Report
|
||||||||
Final Analysis Property Inspections 1385 Fordham Dr. Ste. 105, Virginia Beach VA 23464 |
||||||||
Prepared exclusively for removed for privacy |
||||||||
xxx Cardover Ave. Chesapeake VA 23325 |
||||||||
|
||||||||
Report ID:
xxxx050916 |
||||||||
|
||||||||
Inspection Date:
5/9/2016 |
||||||||
Inspector: |
||||||||
757.495.2300 |
||||||||
Date: 5/9/2016 | Time: 09:00 AM | Report ID: ragle050916 |
Property: xxx Cardover Ave. Chesapeake VA 23325 |
Customer: removed for privacy |
Real Estate Professional: Sharon Milligan All Pros Realty |
Type of Inspection: Home Buyers inspection | Inspection Procedures: American Society of Home Inspectors, Standards of practice Inspector: Reuben
Autery, DPOR
3380000742 | Inspection Restrictions/limitations: None |
General inspection accessibility: Occupied, furnished | All Utility services are on?: Yes | In Attendance: Buyer, Buyers Agent |
Type of building: Single Family (1 story) | Square Feet of conditioned space: 1508 | Age of building (year built): 1973 |
# of Bedrooms: 3 Bedrooms | # of Bathrooms: 1.5 bathrooms | Temperature during inspection: 71 |
Weather: Clear | Ground/Soil surface condition: Dry | Garage: 1.5 car, detached |
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it is satisfactory and appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit does not exists in this home or building.
Information & Disclosures (ID) = Indicated with an ORANGE flag and text. This is Important information you should know about this house or building including, disclosures, alerts, advisories and warnings about typical conditions or circumstances for this home. Not necessarily something abnormal or unusual or in need of action, but none the less critical information that may pose significant concern for health risk, environmental safety or additional cost. These "orange flag" items will also be separately listed in the Information and Disclosure summary page of this report.
Repair or Replace (RR) = Indicated with a RED Flag and text. Corrective action recommended. These items, systems, components or unit is not functioning as intended, defective, broken or otherwise needs further inspection and evaluation by a qualified contractor. Items, components or units that should be repaired, replaced or corrected or otherwise represent significant, unusual, abnormal cost or safety concerns. These "red flag" items will also be separately listed in the DEFECT summary page of this report.
Inspection standards of practice: This inspection was completed in compliance with the professional standards of practice set forth by the American Society of Home inspectors (ASHI) and VA Dept. of Professional Occupation and Regulation (DPOR) for Home Inspectors. These standards and regulations describe the scope, procedures and limitations of a standard home inspection and are provided for your review. Additionally the ASHI standards of practice are included in the appropriate header section of each corresponding system of the report.
Purpose and Objective: This inspection is not technically exhaustive and can not be conclusive of every detail. The primary objective of this building inspection is to identify and report MATERIAL DEFECTS. Material Defects are defined as a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at or beyond the end of its normal useful life is not, in itself, a material defect. Normal wear and tear, maintenance typical defects or deficiencies are not defined as material defects. That is not to say that the home inspector will not report smaller defects such as cracked glass, broken outlets or leaky faucet washers but this is not the primary objective of an inspection. The home inspection is a first look attempt at ascertaining the general condition of a property. While it is the purpose of this inspection to discover and disclose those major items and concerns that may have an adverse impact on the value of this property and the health and safety of it's occupants, it is not an exhaustive list of defects or discrepancies and it certainly should not be used as a punch list of repairs. Repair list and cost estimates should be obtained from contractors. It is important to know that home inspectors are general practitioners with a limited amount of time and capabilities and are primarily focused on major issues in the home. Outside of normal testing and observation, Inspectors do not engage in troubleshooting or diagnostics and can not offer repair advice. Home inspections are limited to visual observations only and does not include technically exhaustive or invasive analysis. However, this report attempts to identify and recommend conditions that should have further evaluation by experts prior to closing or taking ownership.
Typically found on any home and included in any inspection report will be smaller issues, discrepancies, observations and suggestions. These may not be considered serious or significant problems but common to find on all homes and is mostly provided as courtesy in an attempt to give you a more comprehensive understanding of the home. These smaller, typical or common discrepancies are not intended to be all inclusive.
It is the objective of the inspection and report to provide you the means by which you can progress in an informed manner thereby protecting yourself as much as possible before taking ownership of a property. This may mean obtaining further evaluation and repairs by an expert, purchase price adjustments, escrow of funds for repair, or withdrawing from a buyers purchase agreement altogether. If you are subject to an inspection contingency removal purchase addendum your conditions and disposition of removing that contingency should be clearly stated with details of expected outcomes. Furthermore, it should also be stated that any dispositions agreed to should be subjective to your re-inspection and final acceptance of satisfactory completion prior to closing of escrow.
Repairs - No matter how big or small, All repairs, corrections or replacements should be requested to be completed by licensed, qualified professionals with copies of their credentials, licensing, labor and product warranties and receipts of work. It is not recommend that you ask the seller to make the repairs unless they are qualified in the trades and you feel confident that they'll do a good quality job. It should be expected and required that all work be accompanied by any required city permits and inspections. Mostly all work except minor repairs require city permits and inspections. Finally, all repairs should be subject to your re-inspection, satisfaction and approval a couple days before closing. If you are submitting a Property Inspection Contingency Removal Addendum with list of requested repairs (PICRA), you should consider adding the above verbiage to your PICRA because at that point you will be agreeing to buy the house subject to seller repairs and might need assurance they are done correctly.
Reinspection - Due to liability restrictions, reinspections are not the policy of Final Analysis home inspections. All repairs or corrections should be completed by qualified, licensed professional in their trade and should be accompanied by permits, work orders, receipts and warranties. If you feel a reinspection is necessary we can provide on a case by case basis and subject to schedule availability. The property inspection contingency removal addendum (PICRA) should be provided to us when the re-inspection is requested. All re-inspections are subject to a minimum fee of $200 and will be accompanied by an updated report.
NOTICE OF URGENCY: If you are buying this property, any discrepancies, concerns or issues revealed in this report should be resolved to your satisfaction before close of escrow and/or taking possession.
NOTICE - A Termite and moisture inspection was not ordered or completed during this inspection by Final Analysis Property inspections LLC. These are the specific inspections and reports required by some financial institutions to underwrite a mortgage. Termite and Moisture inspections look for and report on the presence of wood damaging organisms. These inspections are typically performed by home inspections company's or pest control companies. It is strongly recommended that you have this completed or have the seller provide termite and moisture clearance documents from a qualified company before taking ownership of the property. Additionally you should have annual inspections for the presence of wood damaging organisms.
Not for 3rd party use - The inspection and report are performed and prepared only for the sole, confidential and exclusive use and possession of the named client(s). Final Analysis Property Inspections accepts no responsibility for use or misrepresentation of this report by third parties who "rely" on the report information but have not directly retained our inspection services and council and are not named in the inspection agreement.
Overview: A thorough home inspection was completed at the subject property in accordance with the American Society Home Inspections (ASHI) standards. The inspection reveals that this dwelling has normal wear and tear. Its structure and systems are generally well built, sound and maintained in good repair with several major system updates less than 5 years old. All observations made and items reported here should be carefully reviewed and considered for correction where needed as they are specific to this home and can have a significant impact on it's condition, safety and value.
The inspector is NOT required to inspect: A. antennae. B. interiors of vent systems, flues, and chimneys that are not readily accessible. C. other installed accessories.
GENERAL ROOF CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Roof service life remaining::
80% - 100% (Very Good - No concerns) |
Roof covering material:
Architectural style asphalt shingles |
Methods used to inspect the roof:
Walked roof Attic |
Roof drainage system:
No roof drainage systems installed |
Attic Ventilation:
Soffit intake vents installed Thermostatically controlled fan 8x8 static roof outlet vents installed |
1.0 |
ROOF MATERIALS
Comments and observations: Inspected |
1.1 |
FLASHINGS
Comments and observations: Inspected |
Disclosure - Roof flashings by design are mostly concealed and therefore inspection is limited to visible areas only followed by examinations and testing of the interiors where leaks are suspected. Some leaks can not be detected and will only show during certain weather conditions. |
1.2 |
SKYLIGHTS, CHIMNEYS and Other ROOF PENETRATIONS
Comments and observations: Inspected |
1.3 |
ROOF DRAINAGE SYSTEMS
Comments and observations: Not Present |
1.4 |
ATTIC VENTILATION
Comments and observations: Inspected |
(1) Improper vent configuration - Power fan is installed in close proximity of static outlet vents (Item 1) . The power exhaust fan should pull air up from the soffit intake
vents thereby cooling the underside of the roof decking. When installed too close or in tandem with other roof vents the power fan will pull make up air from the closest
location and in effect turn the static vents into intake vents thus defeating the purpose of both.
1.4 (Item 1)
|
|
(2) General Statement - Attic ventilation plays an important role in reducing the heat loads in your attic, dissipating trapped moisture and contributing to the overall health
of your attic/roof system. A poorly ventilated attic can reduce HVAC performance, shorten shingle life, and will promote rot of wood materials if moisture can't escape.
Poor eave/soffit vents are the # reason for poor attic ventilation. Typically newer homes are better ventilated but older homes 20+ years, should be reviewed for
improvement. It is important to remember that you need balanced intake vents along with outlet vents for good air flow. Installing just a power fan may not accomplish
this. See more ventilation tips here
Attic is ventilated |
The inspector is NOT required to inspect: A. screening, shutters, awnings, and similar seasonal accessories. B. fences, boundary walls, and similar structures. C. geological and soil conditions. D. recreational facilities. E. outbuildings other than garages and carports. F. seawalls, break-walls, and docks. G. erosion control and earth stabilization measures.
GENERAL EXTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Siding material:
Brick veneer |
Trim materials:
Wood |
Exterior Entry Doors:
Steel Fiberglass |
Driveway:
Concrete |
Evidence of water intrusion at exterior walls windows doors:
No |
2.0 |
Siding, Trim, Eaves, Flashings, Exterior finishes
Comments and observations: Inspected |
Observation - Small piece of vinyl missing from gable peak of shed.
2.0 (Item 1)
|
2.1 |
Doors (exterior)
Comments and observations: Inspected |
(1) Defect - Observed some exterior trim or jamb rot or deterioration at the garage door frame (Item 1) and shed door frame. This type of deterioration is common on most
home and is typically caused by moisture exposure and delayed maintenance but can be costly to repair especially if the door frame has to be replaced. Recommend
further evaluation, repairs and cost estimates be obtained from a qualified repair contractor.
2.1 (Item 1)
2.1 (Item 2)
|
|
(2) Defect - Poor weather seal observed at front entry door. (Item 3) The threshold seal is missing and the frame seals are leaking air. Recommend correction for weather
tightness.
2.1 (Item 3)
|
2.2 |
Windows (exterior)
Comments and observations: Inspected |
2.3 |
Decks, Balconies, Stoops, Steps, Porches, Patio/Sun rooms, Railings
Comments and observations: Inspected |
SAFETY - Handrails missing at front steps and side steps. (Items 1- 2) This information is provided for your safety.
2.3 (Item 1)
2.3 (Item 2)
|
2.4 |
Vegetation, Grading, Drainage, Driveways, Walkways, Retaining walls (With respect to their effect on the condition of the building)
Comments and observations: Inspected |
General Information - Positive grading and drainage are essential to the welfare of a property, and are usually the primary concern of architects and builders. Moisture can deteriorate most surfaces, cause soil movement and erosion, and undermine the structures foundation. The ideal site will be graded to conduct water away from a building. In fact, the ideal building will be surrounded by hard surfaces that slope way from the exterior walls, the interior floors will be several inches higher than the exterior grade, and the building will have gutters and downspouts and a system of drainage designed to prevent any moisture from threatening the foundation or the living space. Unfortunately, many properties do not meet this ideal, conditions on most can generally be improved, and all need to be monitored and maintained to prevent damage. Also, inspectors cannot see inside area drains and do not water-test them, but they can become blocked by debris, occluded by silt, and damaged by movement. Therefore, buyers should question sellers about the functionality of any such system, have it serviced by a specialist, or assume the risk of having a system that does not function well and the damage that might result |
2.5 |
Garage, Garage door, opener safety reverse (if applicable)
Comments and observations: Inspected |
Defect, Safety - The garage overhead door is unbalanced. (Item 1) The garage door should stay in place at any location in it's travel. It should not fly open or drop shut.
An unbalanced garage door can cause personal injury and can cause stress damage to the door system. Recommend professional repairs be completed by a qualified
garage door technician.
2.5 (Item 1)
|
This inspection does not test for or report on the presence of MOLD or other indoor air quality issues or hazards.
GENERAL INTERIOR CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Ceiling construction materials:
Drywall, Sheet rock, Gypsum |
Wall constructuion material:
Gypsum board (typical) |
Floor Covering(s):
Hardwood T&G Ceramic or porcelain tile |
Window Types:
Vinyl or Plastic Double-hung Thermal/Insulated |
Interior Doors / types / styles:
Hollow core Masonite |
Cabinetry:
Wood |
Countertop:
Laminate |
3.0 |
CEILINGS
Comments and observations: Inspected |
3.1 |
WALLS
Comments and observations: Inspected |
3.2 |
FLOORS
Comments and observations: Inspected |
3.3 |
STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments and observations: Not Present |
3.4 |
COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments and observations: Inspected |
3.5 |
DOORS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
3.6 |
WINDOWS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
Replacement vinyl thermal tilt windows 2011 (Item 1)
3.6 (Item 1)
|
GENERAL STRUCTURAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Attic access:
Ceiling scuttle hole |
Method used to observe attic:
From entry |
Crawl space access point:
Exterior Metal |
Method used to observe Crawlspace:
Crawled |
Is there significant structural faiulre/damage/distress was observed/suspected:
NO |
Was there evidence of Harmful Moisture / Water Conditions at foundation/crawlspace:
No |
Was there evidence of Harmful Moisture Conditions in Attic:
No |
Crawlspace ventilation:
foundation vents Adequate |
Foundation type:
Crawlspace |
Floor Structure:
Conventional wood framed |
Wall Structure:
Conventional wood frame |
Columns or Piers:
Masonry block |
Ceiling Structure:
Conventional wood frame |
Roof Structure:
Stick-built 2 X 6 Rafters Plywood Sheathing |
Roof-Type:
Hip |
4.0 |
FOUNDATIONS, SLABS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. Fungus or wood destroying insects)
Comments and observations: Inspected |
(1) Slab / Foundation block is even or below grade level and vulnerable to moisture intrusion and rot damage to wall framing along sill plate at detached garage.
(Items 1 and 2) These areas should be cleared away and inspected for damage. Improvements such as proper grading, drainage and foundation water proofing is also
recommended to be completed by a qualified person or contractor experienced in correcting these conditions.
4.0 (Item 1)
4.0 (Item 2)
|
|
(2) Deficiency - Observed water intrusion via capillary movement at the sill plate of enclosed garage door opening. (Items 3- 4) No damage was detected at this point.
Monitor for future problems.
4.0 (Item 3)
4.0 (Item 4)
|
|
(3) Observation - There is evidence of vermin or rodent nesting/infestation in the attic. Observed feces, nesting materials and insulation tunneling . It is not unusual to see
some level of vermin in these spaces of many homes. Vermin can do significant damage to wiring, insulation and building materials and can block critical ductwork
such as dryer, stove and bathroom vents. Typical suspects are rodents, birds and squirrels. Feces and carcasses can present a health hazard. It is recommended that
you have all holes and entry points blocked or sealed. Pest control operators and exterminators are the professionals that do this kind of work.
4.0 (Item 5)
|
4.1 |
VAPOR RETARDERS (Crawl pace)
Comments and observations: Inspected |
4.2 |
STRUCTURAL FRAMING walls, floors, ceilings (where visible)
Comments and observations: Inspected |
No structural framing distress or failure was visibly detected. |
4.3 |
STRUCTURAL MASONRY, COLUMNS, PIERS, CONCRETE SLAB
Comments and observations: Inspected |
4.4 |
ROOF STRUCTURE AND ATTIC
Comments and observations: Inspected |
4.5 |
CRAWL SPACE VENTILATION (if applicable)
Comments and observations: Inspected |
4.6 |
RETAINER WALLS
Comments and observations: Inspected |
GENERAL PLUMBING SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Water heater service life remaining:
Unknown, Data Illegible |
Probability of plumbing leaks:
Low |
Domestic Potable Water Source (not yard irrigation):
Public (municiple) |
Plumbing waste system:
City sewage |
Water Supply pipe (from street meter):
Copper |
Water Distribution pipes (inside structure - visible areas only):
Copper |
Plumbing Waste / Drain pipe materials:
Galvanized (antiquated, Limited service life) Cast iron (antiquated) AGED |
Domestic hot water source:
Electric storage tank in laundry room |
Water Heater Capacity:
Unknown, data not available |
Hot water temperature:
110-120 deg F. (low) |
Main water shut off location:
Primary valve is at the municipal water meter location Secondary water shut off is in the front flower bed |
5.0 |
PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments and observations: Inspected |
DISCLOSURE: This home contains antiquated style galvanized steel and/or cast iron drains which is typical for the age of construction. (Item 1) However, as
these pipes age, they have a tendency to constrict, drain slowly and back-up do to internal rusting and corrosion. These pipes also corrode from the inside-out. They
can look good from the exterior but may have internal damage. Vertical cast iron waste pipes are that are concealed inside the walls are subject to stress cracks and
may leak internally with no detection. Most pipes are hidden inside the walls or floors and can cause water damages that can go unnoticed for a long time. These older
style pipes have a high probability of failure. Pipes that are inside the walls or buried in the earth, underneath vapor barrier, behind insulation can not be inspected. An
internal video scope inspection or pressure testing is beyond the scope of a home inspection but can be completed by a plumber to determine the pipes internal
condition. Some pipes can be reamed out a few times to restore adequate drainage but this is temporary and eventually the pipes will have to be replaced. These type
of drains have a limited service life of approx 30 - 50 years. Leaks, failure and the need for replacement is inevitable and costly so this should be considered when
buying a house. Replacing these type pipes in homes that are built on concrete slabs can be very expensive because it involved removal of flooring and concrete. Home
with crawlspaces are usually accessible and much easier to replace. This home is on a crawlspace If you are concerned about these pipes you should have them
further evaluated and cost estimates obtained from a licensed, qualified plumber.
5.0 (Item 1)
|
5.1 |
PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments and observations: Inspected |
(1) Defect - Drain is slow or backing up in the hall bath tub (Item 1) . Generally speaking, a fixture should drain at least as quick as it fills to prevent overflow. Drain
restrictions can be a simple trap clog or something more serious which can not be determined by inspection alone. Recommend further evaluation and correction be
completed by a qualified individual or contractor.
5.1 (Item 1)
|
|
(2) Defect - Toilet is loose at floor mounts and drain flange in master bath and is subject to leaking at base (Item 2) . Repairs may involve re-setting the toilet on a new
wax seal. Water can leak into the flooring and cause damage that is not detectable at first. Recommend a qualified licensed plumber repair or correct as needed.
5.1 (Item 2)
|
5.2 |
HOT WATER SYSTEMS
Comments and observations: Inspected |
(1) General safety information about hot water temperatures - Hot water systems can be a scald hazard and a source of disease. Water temperatures higher than
130 deg F. can be a scald hazard. Water temperatures less than 120 deg. F. is considered ideal for the growth of harmful bacteria inside the tank–such as Legionella.
Monitor your hot water temperatures for safety.
Information sources: http://EPA/Legionella: Drinking Water Health Advisory 5.2 (Item 1)
|
|
(2) Observation - the water heater appears newer and is functional but all data has been removed. This is typically done to void warranties on "scratch and dent" sales.
5.2 (Item 2)
5.2 (Item 3)
|
5.3 |
FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)
Comments and observations: Not Present |
5.4 |
MAIN FUEL SHUT OFF (Describe Location)
Comments and observations: Not Present |
5.5 |
SUMP PUMP, LIFT PUMPS, GRINDERS
Comments and observations: Not Present |
The Inspectors shall describe: 1. amperage rating of the service. 2. location of main disconnect(s) and subpanels. 3. Thee presence or absence of smoke alarms and carbon monoxide alarms. 4. the predominant branch circuit wiring method.
The inspector is NOT required to inspect: 1. remote control devices. 2. or test smoke and carbon monoxide alarms, security systems , and other signaling and warning devices. 3. low voltage wiring systems and components. 4. Ancillary wiring systems and components not a part of the primary electrical power distribution system. 5. Solar, geothermal, wind, and other renewable energy systems. B. measure amperage, voltage, and impedance. C. Determine the age and type of smoke alarms and carbon monoxide alarms.
GENERAL ELECTRICAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Electrical inspection limitations:
None, Inspected in accordance with ASHI standards of practice. |
Electrical Service Cable (from utility pole or transformer):
Overhead service Aluminum 4/0 cable |
Location of MAIN electric service panel(s):
utility/laundry room |
Electric service and panel(s):
200 AMP Adequate capacity Main breaker Circuit breakers |
Branch circuit wiring/distribution for 15 and 20 AMP lighting and outlets:
Solid Copper Romex - NM plastic (normal - typical) Grounded (3 prong outlets) "wet area" outlets pre-date GFCI requirments. Recommend update for safety |
SMOKE DETECTORS:
Yes Recommend updating for safety Some Do Not respond |
CARBON MONOXIDE DETECTORS:
No |
6.0 |
SERVICE ENTRANCE CONDUCTORS
Comments and observations: Inspected |
(1) Safety information - This home has on older style overhead electric service feed wire which is typical for the age. Use extreme caution when working with large
trucks, ladders and equipment.
6.0 (Item 1)
|
|
(2) Defect - observed the tree limbs that are in contact with electric service wiring which can cause damage. (Item 2) These limbs should be trimmed away so they are
not close to, or contacting the service wires.
6.0 (Item 2)
|
6.1 |
SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments and observations: Inspected |
6.2 |
BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments and observations: Inspected |
6.3 |
CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments and observations: Inspected |
(1) SAFETY - There are one or more switch covers missing from electrical outlets and wall switches. Covers reduce the risk of fire and shock. Install all outlet and switch
covers where needed.
6.3 (Item 1) master bedroom
6.3 (Item 2) master bathroom
6.3 (Item 3) detached garage
6.3 (Item 4)
|
|
(2) Defect - Amateur light switch installation observed in the hallway. The hallway has a 2 way switch installed on a 3 way circuit which means that when the light switch
is in the off position, the 2nd switch will not respond and vice versa. (Item 1) Recommend professional repairs be completed by a qualified electrical contractor.
6.3 (Item 5)
|
|
(3) Safety - Observed some exposed Romex wiring in garage which is the shed feed wire (Item 5) Wiring in exposed walls must be covered for safety or inside a conduit.
6.3 (Item 6)
|
|
(4) Defect, safety - Electric junction box cover is missing in attic (Item 6) near opening and electrical connections are exposed which could result in shock or
electrocution. Recommend professional repairs be completed by an electrician for safety.
6.3 (Item 7)
|
|
(5) Defect, Safety - Exposed wiring observed at exterior light switch of shed. (Item 8) Recommend professional electrical repairs.
6.3 (Item 8)
|
|
(6) Defect - Electrical conduit pull box is loose, detached and may be an electrical hazard. (Item 9) Recommend professional electrical repairs.
6.3 (Item 9)
|
6.4 |
POLARITY AND GROUNDING OF ELECTRIC RECEPTACLES
Comments and observations: Inspected |
Defect, Safety - An "open ground" reading was detected at the hall bath wall outlet (Item 1). Open grounds are caused by an opening in the ground circuit somewhere
between the affected outlet and the main electric service panel. Typically it's a loose wire on the outlets ground terminal, but it can be anywhere in the circuit such as
an upstream outlet that feeds this outlet. The ground circuit is designed to divert dangerous electricity away from your body and prevent electrocution. Ungrounded
outlets are unsafe and can cause injury or death. It is recommended that this condition be further evaluated and corrected by a qualified electrician.
6.4 (Item 1)
6.4 (Item 2)
|
6.5 |
OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
Information/Disclosure - No Ground Fault Circuit Interrupts , SAFETY - This home was built before GFCI technology was required in certain circuits and therefore
is missing some or all GFCI protection in "wet area" outlets such as; bathrooms, kitchen, exterior, garage, etc. (Items 1- 3) GFCI's protect against shocks and
electrocution. Recommend consider upgrading to modern GFCI's.
GFCI's save lives!.
6.5 (Item 1)
6.5 (Item 2)
6.5 (Item 3)
6.5 (Item 4)
|
6.6 |
OPERATION OF AFCI (ARCH FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
Information/Disclosure - Non Arch Fault Circuit Interrupts , SAFETY - This home was built before AFCI technology and therefore is missing some or all AFCI
protection in bedrooms. AFCI's protect against shorts, sparking and fires.. Recommend consider upgrading to AFCI protection.
“Older homes are statistically more vulnerable to electrical fires. Extra protection for older homes is provided by the gradual replacement, over time, of non-AFCI-protected receptacles with new AFCI-protected ones.” The NEC AFCI's prevent fires. Click here for more information on AFCI's |
6.7 |
SMOKE and CARBON MONOXIDE DETECTORS
Comments and observations: Inspected |
Safety, Repair - One or more installed smoke detectors failed to respond to test. (Items 1 and 2) Have repaired or replaced as needed by a professional. Test again
during final walk-thru inspection then continue to test monthly. Note: these are battery operated only. Properly working smoke detectors save lives.
6.7 (Item 1) first bedroom on right
6.7 (Item 2)
|
AC - The inspector shall: A. open readily openable access panels. B. inspect: 1. central and permanently installed cooling equipment. 2. distribution systems. C. describe: 1. energy source(s). 2. cooling systems.9.2 The inspector is NOT required to: A. inspect electric air cleaning and sanitizing devices. B. determine cooling supply adequacy and distribution balance. C. inspect cooling units that are not permanently installed or that are installed in windows. D. inspect cooling systems using ground-source, water-source, solar, and renewable energy technologies.
FIREPLACES AND FUEL-BURNING APPLIANCES - The inspector shall: A. inspect: 1. fuel-burning fireplaces, stoves, and fireplace inserts. 2. fuel-burning accessories installed in fireplaces. 3. chimneys and vent systems.B. describe systems and components listed in 12.1.A.1 and .2. The inspector is NOT required to: A. inspect: 1. interiors of vent systems, flues, and chimneys that are not readily accessible. 2. fire screens and doors. 3. seals and gaskets. 4. automatic fuel feed devices. 5. mantles and fireplace surrounds. 6. combustion air components and to determine their adequacy. 7. heat distribution assists (gravity fed and fan assisted). 8. fuel-burning fireplaces and appliances located outside the inspected structures. B. determine draft characteristics. C. move fireplace inserts and stoves or firebox contents.
Heat Type:
Heat Pump Forced Air (also provides cool air for AC) |
GENERAL AC/ HP SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
HEAT PUMP / AC - SERVICE LIFE REMAINING::
50% - 80% (Good - No concerns outside of normal maintenance) |
Cooling Equipment Type:
Heat Pump Forced Air (also provides warm air, Heat) |
AC/Heat Pump system(s) performance:
Satisfactory |
AC/Heat Pump system(s) capacity:
Satisfactory |
Number of Central AC / HP systems:
One |
Number of conditioned zones in the house/building:
1 |
Ductwork:
insulated flex duct |
Filter Type:
Disposable |
Types of Fireplaces:
None |
7.0 |
AC COOLING, HEAT PUMP AND AIR HANDLER EQUIPMENT
Comments and observations: Inspected |
(1) Heat Pump equipment performance - The ambient air test was performed by using thermometers on the air handler of Heat pump in cool mode to determine if the
difference in temperatures of the supply and return air are between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air
temperature on your system read 46 degrees (Item 1) , and the return air temperature was 67 degrees (Item 2) . D/T = 21 deg. F. This indicates satisfactory
performance and the system is functioning as designed..
Emergency heat is functional. (Item 3) 7.0 (Item 1)
7.0 (Item 2)
7.0 (Item 3)
|
|
(2) This home is primarily heated and cooled with heat pump system(s). It is the same system and equipment that provides warm air in the winter and cool air in the
summer. When the outside temperature is below 60 deg. F. the system is tested in "heat" mode, When the outside temperature is above 60 deg.F. it is tested in the
"cool" mode. Heat pumps can only be tested in Heat or Cool but not both.
Most heat pump systems contain auxiliary (emergency, back-up) heat, typically electric coils but can be gas or oil. This is always tested winter or summer for response. However, some electronic thermostats when in "cool" mode will not allow manual switching to axillary heat, in which case it can not be tested. |
|
(3) Defect - Some of the electric baseboard heaters do not respond to thermostat.
7.0 (Item 4)
7.0 (Item 5)
|
7.1 |
PRESENCE OF INSTALLED AC/HP SOURCE AIR IN EACH ROOM
Comments and observations: Inspected |
7.2 |
NORMAL OPERATING CONTROLS
Comments and observations: Inspected |
7.3 |
DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments and observations: Inspected |
7.4 |
CHIMNEYS, FLUES AND VENTS (for fireplaces, water heaters or heat systems)
Comments and observations: Not Present |
7.5 |
SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove)
Comments and observations: Not Present |
7.6 |
GAS/LP FIRELOGS AND FIREPLACES
Comments and observations: Not Present |
GENERAL INSULATION CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Attic insulation:
Improvements recommended Loose or blown in fiberglass Approx. R-11 poor |
Wall insulation:
concealed, not visible, not inspected |
Floor System Insulation:
Faced Batts Fiberglass loose, tattered, fallen R-11 |
Bathroom steam vents:
Fan only |
Dryer Power Source:
220 Electric |
Dryer duct (built in):
Metal |
8.0 |
INSULATION IN ATTIC / CEILING
Comments and observations: Inspected |
Attic insulation thickness is marginal or substandard but may have met typical requirements for the age of construction or it could have settled or become packed
down with storage. (Items 1- 2) It does not meet the current standards or R factor of 38 which is recommended by the Department of Energy. The attic or ceilings is
where you'll loose (or gain) the most amount of heat transfer. Consideration should be given to upgrading. It is cost effective and will increase the thermal efficiency of
your home.
Visit these links and learn more about your homes insulation: See US Dept of Energy insulation consumer guide | See Insulation fact Sheet. | See Insulation calculator and estimators | Dept of Energy insulation zone map 8.0 (Item 1)
8.0 (Item 2)
|
8.1 |
WALL INSULATION (if visible)
Comments and observations: Not Inspected |
8.2 |
INSULATION UNDER FLOOR SYSTEM
Comments and observations: Inspected |
Defect - Floor insulation batts are loose or fallen in multiple locations of the crawlspace. Repair or replace as needed.
8.2 (Item 1)
8.2 (Item 2)
8.2 (Item 3)
|
8.3 |
VENTING SYSTEMS (Kitchens, baths and laundry)
Comments and observations: Inspected |
SAFETY ADVISORY- Dryer ducts should be cleaned and inspected annually for proper performance. Dryer ducts are susceptible to clogging and blockage due to lint and moisture build up. Restricted dryer vents will not only reduce drying efficiency, but worse they can overheat and cause fires. If your dryer used a vinyl or foil flex duct connector you should dispose of it and replace with flexible aluminum duct. Aluminum duct is the most efficient type, safest type to reduce fire hazards and the only type recommended by dryer manufactures and by most municipal building codes. Dryer vent installation guidelines See more about dryer duct safety here. |
GENERAL APPLIANCE CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
GARBAGE DISPOSAL:
None installed |
DISHWASHER:
Functional Aging |
RANGE/OVEN/STOVE/COOK TOP:
Functional Aging |
MICROWAVE OVEN (built in):
None installed |
STOVE EXHAUST / RANGE HOOD:
Functional Aging |
9.0 |
DISHWASHER
Comments and observations: Inspected |
9.1 |
RANGES/OVENS/COOKTOPS
Comments and observations: Inspected |
Safety disclosure - The oven/range does not contain an anti-tip bracket and is subject to tipping when the door is opened and weight is placed on the door. (Item 1)
According to the US CPSC (US Consumer Product Safety Commission) stoves without an anti-tip bracket or device can cause injury or death, especially to small
children. Since 1991 it has been required that all electric and gas ranges have an anti-tip device installed when the oven/range is installed. This information is provided
for your safety.
9.1 (Item 1)
9.1 (Item 2)
9.1 (Item 3)
|
9.2 |
RANGE HOOD
Comments and observations: Inspected |
9.3 |
GARBAGE DISPOSAL UNIT
Comments and observations: Not Present |
9.4 |
MICROWAVE COOKING EQUIPMENT
Comments and observations: Not Present |