Property Inspection Report
|
||||||||
Final Analysis Property Inspections 1385 Fordham Dr. Ste. 105, Virginia Beach VA 23464 |
||||||||
Prepared exclusively for removed for privacy |
||||||||
*** Harlequin Way Chesapeake VA 23321 |
||||||||
|
||||||||
Report ID:
042017 |
||||||||
|
||||||||
Inspection Date:
4/20/2017 |
||||||||
Inspector: Zachary Zinn, State Lic# 3380001182 | ||||||||
757.495.2300 |
||||||||
Date: 4/20/2017 | Time: 01:00 PM | Report ID: 042017 |
Property: *** Harlequin Way Chesapeake VA 23321 |
Customer: removed for privacy |
Real Estate Professional: Sherry Menard |
Type of Inspection: Home Buyers inspection | Inspectors: Zachary Zinn, State Lic# 3380001182 | Inspection Procedures: American Society of Home Inspectors, Standards of practice |
Inspection Restrictions/limitations: None | General inspection accessibility: Vaccant, Unoccupied | All Utility services are on?: Yes |
In Attendance: Buyer, Buyers Agent | Type of building: Single Family (2 story) | Square Feet of conditioned space: 2959 |
Age of building (year built): 1993 | # of Bedrooms: 4 Bedrooms | # of Bathrooms: 2.5 bathrooms |
Temperature during inspection: 75 | Weather: Clear | Ground/Soil surface condition: Dry |
Garage: 2 car, Attached |
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it is satisfactory and appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit does not exists in this home or building.
Information & Disclosures (ID) = Indicated with an ORANGE flag and text. This is Important information you should know about this house or building including, disclosures, alerts, advisories and warnings about typical conditions or circumstances for this home. Not necessarily something abnormal or unusual or in need of action, but none the less critical information that may pose significant concern for health risk, environmental safety or additional cost. These "orange flag" items will also be separately listed in the Information and Disclosure summary page of this report.
Repair or Replace (RR) = Indicated with a RED Flag and text. Corrective action recommended. These items, systems, components or unit is not functioning as intended, defective, broken or otherwise needs further inspection and evaluation by a qualified contractor. Items, components or units that should be repaired, replaced or corrected or otherwise represent significant, unusual, abnormal cost or safety concerns. These "red flag" items will also be separately listed in the DEFECT summary page of this report.
Inspection standards of practice: This inspection was completed in compliance with the professional standards of practice set forth by the American Society of Home inspectors (ASHI) and VA Dept. of Professional Occupation and Regulation (DPOR) for Home Inspectors. These standards and regulations describe the scope, procedures and limitations of a standard home inspection and are provided for your review. Additionally the ASHI standards of practice are included in the appropriate header section of each corresponding system of the report.
Purpose and Objective: This inspection is not technically exhaustive and can not be conclusive of every detail. The primary objective of this building inspection is to identify and report MATERIAL DEFECTS. Material Defects are defined as a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at or beyond the end of its normal useful life is not, in itself, a material defect. Normal wear and tear, maintenance typical defects or deficiencies are not defined as material defects. That is not to say that the home inspector will not report smaller defects such as cracked glass, broken outlets or leaky faucet washers but this is not the primary objective of an inspection. The home inspection is a first look attempt at ascertaining the general condition of a property. While it is the purpose of this inspection to discover and disclose those major items and concerns that may have an adverse impact on the value of this property and the health and safety of it's occupants, it is not an exhaustive list of defects or discrepancies and it certainly should not be used as a punch list of repairs. Repair list and cost estimates should be obtained from contractors. It is important to know that home inspectors are general practitioners with a limited amount of time and capabilities and are primarily focused on major issues in the home. Outside of normal testing and observation, Inspectors do not engage in troubleshooting or diagnostics and can not offer repair advice. Home inspections are limited to visual observations only and does not include technically exhaustive or invasive analysis. However, this report attempts to identify and recommend conditions that should have further evaluation by experts prior to closing or taking ownership.
Typically found on any home and included in any inspection report will be smaller issues, discrepancies, observations and suggestions. These may not be considered serious or significant problems but common to find on all homes and is mostly provided as courtesy in an attempt to give you a more comprehensive understanding of the home. These smaller, typical or common discrepancies are not intended to be all inclusive.
It is the objective of the inspection and report to provide you the means by which you can progress in an informed manner thereby protecting yourself as much as possible before taking ownership of a property. This may mean obtaining further evaluation and repairs by an expert, purchase price adjustments, escrow of funds for repair, or withdrawing from a buyers purchase agreement altogether. If you are subject to an inspection contingency removal purchase addendum your conditions and disposition of removing that contingency should be clearly stated with details of expected outcomes. Furthermore, it should also be stated that any dispositions agreed to should be subjective to your re-inspection and final acceptance of satisfactory completion prior to closing of escrow.
Repairs - No matter how big or small, All repairs, corrections or replacements should be requested to be completed by licensed, qualified professionals with copies of their credentials, licensing, labor and product warranties and receipts of work. It is not recommend that you ask the seller to make the repairs unless they are qualified in the trades and you feel confident that they'll do a good quality job. It should be expected and required that all work be accompanied by any required city permits and inspections. Mostly all work except minor repairs require city permits and inspections. Finally, all repairs should be subject to your re-inspection, satisfaction and approval a couple days before closing. If you are submitting a Property Inspection Contingency Removal Addendum with list of requested repairs (PICRA), you should consider adding the above verbiage to your PICRA because at that point you will be agreeing to buy the house subject to seller repairs and might need assurance they are done correctly.
Reinspection - Due to liability restrictions, reinspections are not the policy of Final Analysis home inspections. All repairs or corrections should be completed by qualified, licensed professional in their trade and should be accompanied by permits, work orders, receipts and warranties. If you feel a reinspection is necessary we can provide on a case by case basis and subject to schedule availability. The property inspection contingency removal addendum (PICRA) should be provided to us when the re-inspection is requested. All re-inspections are subject to a minimum fee of $225 and will be accompanied by an updated report.
NOTICE OF URGENCY: If you are buying this property, any discrepancies, concerns or issues revealed in this report should be resolved to your satisfaction before close of escrow and/or taking possession.
NOTICE - A Termite and moisture inspection was not ordered or completed during this inspection by Final Analysis Property inspections LLC. These are the specific inspections and reports required by some financial institutions to underwrite a mortgage. Termite and Moisture inspections look for and report on the presence of wood damaging organisms. These inspections are typically performed by home inspections company's or pest control companies. It is strongly recommended that you have this completed or have the seller provide termite and moisture clearance documents from a qualified company before taking ownership of the property. Additionally you should have annual inspections for the presence of wood damaging organisms.
Not for 3rd party use - The inspection and report are performed and prepared only for the sole, confidential and exclusive use and possession of the named client(s). Final Analysis Property Inspections accepts no responsibility for use or misrepresentation of this report by third parties who "rely" on the report information but have not directly retained our inspection services and council and are not named in the inspection agreement.
Overview: A thorough home inspection was completed at the subject property in accordance with the American Society Home Inspections (ASHI) standards. The inspection reveals that this dwelling has above normal wear and tear. Its structure and systems are generally sound and well built, with neglected maintenance and discrepancies and deficiencies reported. All observations made and items reported here should be carefully reviewed and considered for correction where needed as they are specific to this home and can have a significant impact on it's condition, safety and value.
The inspector is NOT required to inspect: A. antennae. B. interiors of vent systems, flues, and chimneys that are not readily accessible. C. other installed accessories.
~ Overview Photos ~
GENERAL ROOF CONDITION / RATING:
Fair ( Functional, some concerns, maintenance/repairs needed, aging, worn.) |
Roof service life remaining::
20% or less (plan for replacement, consider cost) |
Roof covering material:
Architectural style asphalt shingles |
Methods used to inspect the roof:
Walked roof Attic |
Roof drainage system:
No roof drainage systems installed |
Attic Ventilation:
Soffit intake vents installed 8x8 static roof outlet vents installed |
1.0 |
ROOF MATERIALS
Comments and observations: Inspected |
Aging Roof - The roof shingle covering is old, and its service life has expired. Observed during inspection
are broken, missing shingles, fissures, fractures, dried, brittle shingles and mildew growth (Items 1-5).
The shingle covering is in need of replacement and this should be taken into consideration. If
replacement is delayed leaks may develop and the need for patching and repairs will accelerate.
Recommend further evaluation and replacement cost estimates be obtained from a qualified roofing
contractor. Note I: It is not uncommon for roofers to discover hidden rot damage or delamination of roof
decking during replacement and they will charge extra for this. Note II: all flashings, roof vents and soil
vent boots should be replaced during a new roof installation.
Implications: Water damage to property. Time frame: Immediate Cost: High 1.0 (Item 1)
1.0 (Item 2)
1.0 (Item 3)
1.0 (Item 4)
1.0 (Item 5)
|
1.1 |
FLASHINGS
Comments and observations: Inspected |
Disclosure - Roof flashings by design are mostly concealed and therefore inspection is limited to visible areas only followed by examinations and testing of the interiors where leaks are suspected. Some leaks can not be detected and will only show during certain weather conditions. |
1.2 |
SKYLIGHTS, CHIMNEYS and Other ROOF PENETRATIONS
Comments and observations: Inspected |
1.3 |
ROOF DRAINAGE SYSTEMS
Comments and observations: Inspected |
Deficiency - The is covered in debris in areas, not draining as designed and need to be cleaned (Items 1-2). The debris can trap water and cause premature deterioration or leaks. Recommend professional
cleaning, inspection and any repair maintenance as needed.
Implications: Water damage to property. Time frame: ongoing maintenance Cost: Low 1.3 (Item 1)
1.3 (Item 2)
|
1.4 |
ATTIC VENTILATION
Comments and observations: Inspected |
General Statement - Attic ventilation plays an important role in reducing the heat loads in your attic, dissipating trapped moisture and contributing to the overall health of your attic/roof system. A poorly ventilated attic can reduce HVAC performance, shorten shingle life, and will promote rot of wood materials if moisture can't escape. Poor eave/soffit vents are the # reason for poor attic ventilation. Typically newer homes are better ventilated but older homes 20+ years, should be reviewed for improvement. It is important to remember that you need balanced intake vents along with outlet vents for good air flow. Installing just a power fan may not accomplish this. See more ventilation tips here Attic is ventilated |
The inspector is NOT required to inspect: A. screening, shutters, awnings, and similar seasonal accessories. B. fences, boundary walls, and similar structures. C. geological and soil conditions. D. recreational facilities. E. outbuildings other than garages and carports. F. seawalls, break-walls, and docks. G. erosion control and earth stabilization measures.
~ Overview Photos ~
GENERAL EXTERIOR CONDITION / RATING:
Fair ( Functional, some concerns, amateur work, maintenance/repairs needed, aging, worn.) |
Siding material:
Vinyl |
Trim materials:
Wood |
Exterior Entry Doors:
Steel |
Appurtenance:
Deck with steps Covered porch Framed screen/patio room |
Driveway:
Concrete |
Evidence of water intrusion at exterior walls windows doors:
No |
2.0 |
Siding, Trim, Eaves, Flashings, Exterior finishes
Comments and observations: Inspected |
Defect - Exterior trim paint has suffered delayed maintenance and is deteriorating and failing at exterior
wood trim on fascia's, rakes and frieze boards. (Items 1- 4) Observed paint oxidation,advanced flaking
and peeling, exposed wood and some soft wood or rot. Recommend professional prep, repairs and re-sealing with a fresh coat of paint to prevent further deterioration. Cost associated with this repair can be
significant and should be taken into consideration.
2.0 (Item 1)
2.0 (Item 2)
2.0 (Item 3)
2.0 (Item 4)
|
2.1 |
Doors (exterior)
Comments and observations: Inspected |
(1) Defect - Observed some exterior trim or jamb rot or deterioration at the garage utility door frame (Items 1-2). The door threshold is also damaged and pulled away from the door jamb (Item 3). The door is also
beginning to rust and is missing the sweeper allowing air and water infiltration from the exterior (Item 4).
This type of deterioration is common on most home and is typically caused by moisture exposure and
delayed maintenance but can be costly to repair especially if the door frame has to be replaced.
Recommend further evaluation, repairs and cost estimates be obtained from a qualified repair contractor.
2.1 (Item 1)
2.1 (Item 2)
2.1 (Item 3)
2.1 (Item 4)
|
|
(2) Defect - The threshold at the patio door is warped and damaged (Item 5). A loose threshold will allow
water and air infiltration. Recommend further evaluation and repairs be completed by a qualified door
contractor.
2.1 (Item 5)
|
|
(3) Defect - Observed some exterior trim or jamb rot or deterioration at the patio door frame (Item 6). This
type of deterioration is common on most home and is typically caused by moisture exposure and delayed
maintenance but can be costly to repair especially if the door frame has to be replaced. Recommend
further evaluation, repairs and cost estimates be obtained from a qualified repair contractor.
2.1 (Item 6)
|
2.2 |
Windows (exterior)
Comments and observations: Inspected |
2.3 |
Decks, Balconies, Stoops, Steps, Porches, Patio/Sun rooms, Railings
Comments and observations: Inspected |
Defect - Substandard construction. The patio room is built on top a deck like structure (Item 1) with
wooden post that are subject to rot and structural failure of the patio room. (Item 2) These rooms should
be supported by a permanent foundation of footers, masonry piers and girder beams. Recommend further
evaluation and cost estimates be obtained by a building contractor.
2.3 (Item 1)
2.3 (Item 2)
|
2.4 |
Vegetation, Grading, Drainage, Driveways, Walkways, Retaining walls (With respect to their effect on the condition of the building)
Comments and observations: Inspected |
(1) General Information - Positive grading and drainage are essential to the welfare of a property, and are usually the primary concern of architects and builders. Moisture can deteriorate most surfaces, cause soil movement and erosion, and undermine the structures foundation. The ideal site will be graded to conduct water away from a building. In fact, the ideal building will be surrounded by hard surfaces that slope way from the exterior walls, the interior floors will be several inches higher than the exterior grade, and the building will have gutters and downspouts and a system of drainage designed to prevent any moisture from threatening the foundation or the living space. Unfortunately, many properties do not meet this ideal, conditions on most can generally be improved, and all need to be monitored and maintained to prevent damage. Also, inspectors cannot see inside area drains and do not water-test them, but they can become blocked by debris, occluded by silt, and damaged by movement. Therefore, buyers should question sellers about the functionality of any such system, have it serviced by a specialist, or assume the risk of having a system that does not function well and the damage that might result | |
(2) Observation - Loose and hanging tree branch is subject to detachment and personal injury. (Item 1)
2.4 (Item 1)
|
2.5 |
Garage, Garage door, opener safety reverse (if applicable)
Comments and observations: Inspected |
(1) Defect - Right garage door is non-operable. The wheels are missing or damaged, and the cables are not
in the guide wheels (Items 1-3). Recommend repairs be completed by a qualified garage door contractor.
2.5 (Item 1)
2.5 (Item 2)
2.5 (Item 3)
|
|
(2) Defect - Observed physical damage at the left garage door (viewed from exterior) panel or framing which
can result in door failure and/or personal injury (Item 4). Recommend further evaluation and repairs or
replacement be completed by a qualified overhead door contractor.
2.5 (Item 4)
|
This inspection does not test for or report on the presence of MOLD or other indoor air quality issues or hazards.
~ Overview Photos ~
GENERAL INTERIOR CONDITION / RATING:
Fair ( Functional, some concerns, amateur work, maintenance/repairs needed, aging, worn.) |
Ceiling construction materials:
Drywall, Sheet rock, Gypsum Plaster veneer |
Wall constructuion material:
Gypsum board (typical) Plaster veneer finish |
Floor Covering(s):
Carpet Laminated T&G Ceramic or porcelain tile |
Window Types:
Vinyl or Plastic Tilt feature Single-hung Thermal/Insulated |
Interior Doors / types / styles:
Hollow core Masonite Raised panel |
Cabinetry:
Wood |
Countertop:
Laminate |
3.0 |
CEILINGS
Comments and observations: Inspected |
(1) Satisfactory - The visible areas of the ceilings are generally in typical condition and performing as intended, consistent with normal wear and tear and the age and style of construction. The ceilings were checked for loose gypsum board/plaster and severe cracking. All ceilings were infrared scanned with thermal imaging, all stains or water marks are tested for active moisture using a moisture meter. Items that are cosmetic in nature such as soiled paint, cracked tape joints, normal plaster cracking are considered self evident and not reported unless they are extreme and affecting the design and function of the ceiling. | |
(2) Cosmetic - Observed tape joint separation in the living room ceiling (Item 1). Recommend repairs as
desired by qualified drywall contractor.
3.0 (Item 1)
|
3.1 |
WALLS
Comments and observations: Inspected |
Satisfactory - The visible areas of the walls are generally in typical condition and performing as intended, consistent with normal wear and tear and the age and style of construction. The walls were checked for loose gypsum board/plaster, water damage and severe cracking. All walls were infrared scanned with thermal imaging, all stains or water marks are tested for active moisture using a moisture meter. Items that are cosmetic in nature such as soiled paint, cracked tape joints, picture holes and normal plaster cracking are considered self evident and not reported unless they are extreme and affecting the design and function of the walls. |
3.2 |
FLOORS
Comments and observations: Inspected |
(1) Satisfactory - Visible areas of the flooring are in typical condition and performing as intended, consistent with the age and style of construction. We do not report on normal wear and tear or cosmetic conditions of the flooring unless it is extreme. | |
(2) Deficiency - Located lifted sub floor in the living room causing it to shift and squeak (Item 1).
Recommend repairs be completed by a qualified flooring contractor.
3.2 (Item 1)
|
|
(3) Defect - The stone transition in the upstairs hall bathroom is crack and physically damaged making it a
trip and fall hazard (Item 2). Recommend repairs be completed by a qualified flooring contractor.
3.2 (Item 2)
|
3.3 |
STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments and observations: Inspected |
Inspection - In addition to physical examination of structure, design and soundness, These items were evaluated for safety features such as loose/improper hand/guard rails, head clearances, loose or inconsistent steps and proper lighting. |
3.4 |
COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Comments and observations: Inspected |
(1) Testing - Physical examination of the cabinets, their doors and drawers and counter tops included hardware, improper fastening and normal operation. Conditions that are cosmetic in nature such as finishes, soil, normal wear and tear are considered self evident and not reported. | |
(2) Defect - Island counter top and cabinet are loose and detached and is a personal injury hazard (Item 1).
Recommend repairs be completed by a qualified cabinet contractor.
3.4 (Item 1)
|
3.5 |
DOORS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
(1) Testing - In addition to physical examination, all interior doors were tested for open, close, balance, loose hinges, square and latching operation. Conditions that are cosmetic in nature such as finishes, soil, normal wear and tear are considered self evident and not reported. | |
(2) Defect - The master bathroom shower door is missing door guides which keeps the door panels in place.
The door can possibly detach from the top rail and fall, making it a personal injury hazard. Recommend
repairs be completed by a qualified contractor.
3.5 (Item 1)
|
3.6 |
WINDOWS (REPRESENTATIVE NUMBER)
Comments and observations: Inspected |
(1) Testing - In addition to physical examination, all windows were tested for open, close, tilt, latch, weather seal, sash spring balance and fire egress operation. Any broken glass, faulty sash operation and thermal seal failure is reported as a defect below. | |
(2) Defect - Insulated glass (IG unit) seal failure - The glazing seal has failed causing etching, fogged
appearance and condensation between the double panes of glass (Items 1-9). The insulated double
pane glazing has compromised thermal properties in addition to permanent cosmetic
damage. The typical repair is to replace the thermal insulated glass (IG unit) with new. There are
several local service providers / contractors that specialize in this type of repair. It is recommended you
contact them for further evaluation, assess all windows for thermal failure and to obtain repair cost
estimates.
Be Advised: Evidence of seal failure is affected by environmental temperature and humidity levels making it difficult to detect and not always visible during the inspection but may surface later. The photos and identification of certain windows in this report are for illustration purposes and are not intended to be a complete list. Recommend additional inspections before close of escrow be completed during your walk through inspection. Additionally, if multiple windows in the home have seal failure it should be expected that other windows are likely to fail in the future do to age and poor factory design. 3.6 (Item 1)
3.6 (Item 2)
3.6 (Item 3)
3.6 (Item 4)
3.6 (Item 5)
3.6 (Item 6)
3.6 (Item 7)
3.6 (Item 8)
3.6 (Item 9)
|
~ Overview Photos ~
GENERAL STRUCTURAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Structural inspection limitations:
None |
Method used to observe attic:
Walked |
Crawl space access point:
Garage |
Method used to observe Crawlspace:
Crawled |
Is there significant structural faiulre/damage/distress was observed/suspected:
NO |
Was there evidence of Termits- Powder post beetles or wood destroying fungus- mold- mildew- spores:
No termite or wood destroying insect inspection performed |
Was there evidence of Harmful Moisture / Water Conditions at foundation/crawlspace:
No |
Was there evidence of Harmful Moisture Conditions in Attic:
No |
Crawlspace ventilation:
foundation vents |
Foundation type:
Crawlspace |
Floor Structure:
Dimensional Wood joists (trad. 2x's) Dimensional wood girders (2x's or 6x's) |
Wall Structure:
Concealed, Not visible, Not determined |
Columns or Piers:
Masonry block |
Ceiling Structure:
Enclosed, Concealed, Not visible |
Roof Structure:
Stick-built 2 X 8 Rafters Sheathing Oriented strand board (OSB) |
Roof-Type:
Gable |
4.0 |
FOUNDATIONS, SLABS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. Fungus or wood destroying insects)
Comments and observations: Inspected |
Defect - Evidence of water intrusion and minor damage under the rear entry door in the crawlspace (Item
2). Recommend further evaluation and repairs to be completed by a qualified contractor.
4.0 (Item 1)
|
4.1 |
VAPOR RETARDERS (Crawl pace)
Comments and observations: Inspected |
Defect-The vapor barrier (plastic) on the crawlspace ground is missing from several locations. A vapor
barrier provides added protection to the floor system and building components from harmful moisture,
dampness and evaporation that can enter from ground. vapor barrier should be at least 6mil and provide
100% coverage. It should be trimmed and fit around columns, overlapped at seams and pinned down to
prevent movement or separation. A qualified contractor should inspect and repair as needed.
4.1 (Item 1)
|
4.2 |
STRUCTURAL FRAMING walls, floors, ceilings (where visible)
Comments and observations: Inspected |
No structural framing distress or failure was visibly detected. |
4.3 |
STRUCTURAL MASONRY, COLUMNS, PIERS, CONCRETE SLAB
Comments and observations: Inspected |
Defect - Masonry pier in the vicinity under the dining room has shifted and separated at the base and no
longer providing support (Items 1-2). This pier should be re-centered and reseated and shimmed tightly to
the girder (Item 3). Recommend repairs be completed by a qualified structural contractor.
4.3 (Item 1)
4.3 (Item 2)
4.3 (Item 3)
|
4.4 |
ROOF STRUCTURE AND ATTIC
Comments and observations: Inspected |
4.5 |
CRAWL SPACE VENTILATION (if applicable)
Comments and observations: Inspected |
~ Overview Photos ~
GENERAL PLUMBING SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Water heater service life remaining:
80% - 100% (Very Good - No concerns) |
Probability of plumbing leaks:
Low |
Domestic Potable Water Source (not yard irrigation):
Public (municiple) |
Plumbing waste system:
City sewage |
Water Supply pipe (from street meter):
Polybutylene (PB) (inferior materials) |
Water Distribution pipes (inside structure - visible areas only):
Polybutylene (PB) (inferior materials) |
Plumbing Waste / Drain pipe materials:
PVC (Polyvinyl Chloride) |
Domestic hot water source:
Natural Gas storage tank (quicker recovery) |
Water Heater Capacity:
50 Gallon (2-3 people) |
Hot water temperature:
110-120 deg F. (low) |
Gas piping on premises:
Natural Gas |
Main water shut off location:
Primary valve is at the municipal water meter location Secondary water shut off is in the garage |
Main fuel shut off:
At the gas meter |
5.0 |
PLUMBING DRAIN, WASTE AND VENT SYSTEMS
Comments and observations: Inspected |
Testing - In addition to physical examination, the inspector tested the drain pipes by running all faucets and flushing toilets continually during the inspection while watching for slow or backing up drains or leaks and followed up with thermal imaging scanning and moisture meter test of concealed areas such as the ceilings below a bathroom. |
5.1 |
PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Comments and observations: Inspected |
(1) Testing - In addition to physical examination, the inspector tested the water supply pipes and fixtures by running all faucets and flushing toilets continually during the inspection while monitoring for slow flow, pressure drops and leaky faucets. We also took pressure readings with all faucets open and all faucets closed looking for a range of 40-60psi. this is followed up with thermal imaging scanning and moisture meter test of concealed areas such as the ceilings below a bathroom. | |
(2) Polybutylene plastic plumbing supply lines (PB) are installed in the subject house. (Item 1)
Polybutylene (AKA Quest pipes) millions of homes where plumbed with PB in the 80's and 90's but
installations ceased in the middle 90's when it was realized to be an inferior piping due to it's higher
than normal failure rate. Plastic insert fittings were used in the early years which had a very high
failure rate. Copper and Brass insert fittings used in later years have dramatically reduced the failure
rate but by then it was too late and was abolished from use altogether. This subject house has copper
fittings which have a much higher success rate but still carries a negative stigma surrounding potential
failure.. Many homes have been completely re-plumbed by now, especially the ones with plastic
fittings. Re-plumb can be very expensive. Most homes are re-plumbed using PEX or CPVC pipes but
some use copper. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com Please note that much of the information on the web about
PB is "for profit" so take it with a grain of salt.
Implications: property damage Time frame: discretionary but urgent Cost: High (8k-10k to re-plumb) 5.1 (Item 1)
|
|
(3) Polybutylene plastic street supply pipe - Polybutylene (PB) plastic plumbing "yard service pipe from
meter is installed at this house. Polybutylene has been used in this area for many years, but has had a
higher than normal failure rate, and is no longer being widely used. The blue PB used for yard service has
a fairly good performance record relative the the grey PB used inside some homes. Any use of PB is
disclosed for your information. For further details contact the Consumer Plumbing Recovery center at 1-800-392-7591 or the web at http://www.pbpipe.com
5.1 (Item 2)
|
|
(4) Disclosure - Some or all of the faucets and fixtures in this home are aging, worn from normal wear and
subject to leak. It's not uncommon through normal aging and wear for the seals, gaskets and washers to
fail after about 20 years of service. It is recommended that you monitor the plumbing devices and
consider some preventative maintenance by changing washers, tightening or updating faucets, toilets,
tanks before you have a leak.
Implications: leaks, water damage. Time frame: Discretionary Cost: low to moderate |
|
(5) Defect - Observed loose hanging, unsecured water piping at the at the water heater location (Item 3).
Pipes that are not secured can become loose or leak at fittings from pipe hammer, whip or strain.
Recommend that all piping be secured as required using approved methods and materials and completed
by a qualified contractor.
Implications: water leaks, property damage. Time frame: earliest convenience. Cost: Low 5.1 (Item 3)
|
|
(6) FYI - The secondary main water cut off is in the garage. (Item 4)
5.1 (Item 4)
|
|
(7) Disclosure - This home contains a private well pump and / or irrigation system (Item 5). This is an
accessory system that provides non-potable water and is not part of the homes domestic plumbing.
Private well pumps and irrigation systems are beyond the scope and standards of practice of a normal
home inspection and are not included in this inspection. If this system is important to you, It is
recommend that you seek further information and demonstration of this system from the current owner or
a yard irrigation specialist.
5.1 (Item 5)
|
|
(8) Defect - Backflow preventer device is either inoperable or missing from hose bib (Item 6). Backflow
preventers are required to prevent bacterial cross connect and contamination of municipal water supplies
(Item 7). Backflow preventers have been required since the 1980's. Older homes did not have them
installed. Recommend professional corrections be completed by a qualified plumbing contractor.
5.1 (Item 6)
5.1 (Item 7)
|
|
(9) Observation - The master bath jetted tub responded to testing at the time of the inspection. (Item 8)
5.1 (Item 8)
|
5.2 |
HOT WATER SYSTEMS
Comments and observations: Inspected |
(1) General safety information about hot water temperatures - Hot water systems can be a scald
hazard and a source of disease. Water temperatures higher than 130 deg F. can be a scald hazard.
Water temperatures less than 120 deg. F. is considered ideal for the growth of harmful bacteria inside
the tank–such as Legionella. Monitor your hot water temperatures for safety.
Information sources: http://EPA/Legionella: Drinking Water Health Advisory |
|
(2) Deficiency - The hot water temperature is a little low and may indicate a problem with the water heater or
the temperature setting is too low (Item 1). The water temperature should be between 120 and 130 deg F.
Recommend further evaluation and correct as needed.
5.2 (Item 1)
|
5.3 |
FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)
Comments and observations: Inspected |
Defect - Observed loose hanging, unsecured gas piping at the HVAC gas pack outside location (Item 1).
Pipes that are not secured can become loose or leak at fittings from pipe hammer, whip or strain.
Recommend that all piping be secured as required using approved methods and materials and completed
by a qualified contractor.
Implications: gas leaks, property damage. Time frame: earliest convenience. Cost: Low 5.3 (Item 1)
|
5.4 |
MAIN FUEL SHUT OFF (Describe Location)
Comments and observations: Inspected |
FYI - The main fuel shut off is at the gas meter. |
The Inspectors shall describe: 1. amperage rating of the service. 2. location of main disconnect(s) and subpanels. 3. Thee presence or absence of smoke alarms and carbon monoxide alarms. 4. the predominant branch circuit wiring method.
The inspector is NOT required to inspect: 1. remote control devices. 2. or test smoke and carbon monoxide alarms, security systems , and other signaling and warning devices. 3. low voltage wiring systems and components. 4. Ancillary wiring systems and components not a part of the primary electrical power distribution system. 5. Solar, geothermal, wind, and other renewable energy systems. B. measure amperage, voltage, and impedance. C. Determine the age and type of smoke alarms and carbon monoxide alarms.
~ Overview Photos ~
GENERAL ELECTRICAL CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Electrical inspection limitations:
None, Inspected in accordance with ASHI standards of practice. |
Electrical Service Cable (from utility pole or transformer):
Below ground Aluminum 2/0 cable |
Location of MAIN electric service panel(s):
garage |
Electric service and panel(s):
150 AMP Adequate capacity Main breaker Circuit breakers |
Branch circuit wiring/distribution for 15 and 20 AMP lighting and outlets:
Solid Copper Romex - NM plastic (normal - typical) Grounded (3 prong outlets) |
SMOKE DETECTORS:
Yes Recommend updating for safety |
CARBON MONOXIDE DETECTORS:
Recommend updating for safety No CO detectors installed |
6.0 |
SERVICE ENTRANCE CONDUCTORS
Comments and observations: Inspected |
6.1 |
SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments and observations: Inspected |
Inspection - The main electric panels and sub panels have been examined for proper labeling, over fusing, melting, scorching, improper breakers/fuses, cabinet condition, improper workmanship and proper grounding. |
6.2 |
BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Comments and observations: Inspected |
6.3 |
CONNECTED DEVICES AND FIXTURES (Observed from an accesible, representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments and observations: Inspected |
(1) Testing and evaluation - In addition to visual examination, all the electric outlets were tested for
power, grounding, scorching, paint coverage, reversed wiring, GFCI / AFCI trip and reset. Switches and
fixtures are tested for response but be advised some switches may not be in use or bulbs may be
blown. Not all receptacles or fixtures can be inspected or tested in homes that are occupied because
they may not be accessible. The Inspection of outlets and devices is only intended to provide a
representative example of their general condition. Electrical devices can break or stop working between
now and closing so it's important that you check again during your final walk through inspection. Final
Analysis Home inspections does not guarantee that every single outlet, switch and light fixture will
continue to work properly after the inspection.
Electric device life expectancy - Electrical switches, outlets and devices wear out after about 20 years of service. Final Analysis does not report normal wear and tear of electrical devices unless it is failed during the inspection. If your outlets and switches are 20 years old or greater, you should plan and budget for replacement. |
|
(2) Defect, Safety - Conduit brackets missing. Observed a loose, detached conduit at the outside HVAC
gas pack (Item 1). Conduits must be securely attached with brackets to prevent movement and strain.
Recommend evaluation and repairs be completed by a qualified electrician using approved methods and
materials.
Implications: Shock hazard, water entry, failed equipment. Time frame: Immediate. Cost: low 6.3 (Item 1)
|
|
(3) Safety, Amateur workmanship - Observed loose and hanging exterior romex wiring that is being used
as a plug in cord for the back yard lamp (Items 2 and 3). All romex wiring must be concealed or buried to
prevent personal injury and electrocution hazard. Recommend professional repairs be completed by a
qualified electrical contractor using approved methods and materials.
6.3 (Item 2)
6.3 (Item 3)
|
|
(4) Safety - One or more electric outlets have been painted (Item 4). Paint can cause an insulating
affect on terminal surfaces which can cause high resistance, overheating and burning at receptacle plug.
Typical correction would be to replace all affected outlets. Have all receptacles further reviewed and
repaired/replaced as needed for safety by a licensed, qualified electrical contractor.
6.3 (Item 4)
|
|
(5) Defect - The front porch outlet is missing half of its cover and is subject exterior elements such as rain
water and is a sock and electrocution hazard (Item 5). Recommend repairs be completed by a qualified
electrical contractor.
6.3 (Item 5)
|
6.4 |
POLARITY AND GROUNDING OF ELECTRIC RECEPTACLES
Comments and observations: Inspected |
Testing - In addition to physical condition, all accessible electric outlets were tested for reversed wiring, power available, and proper grounding. House wiring is subjective to the homes age but we report antiquated wiring systems so you'll know. |
6.5 |
OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Inspected |
Safety - Old GFCI outlet in the garage the time it takes to trip is delayed when tested which makes it a
shock and electrocution hazard (Item 1). Have replaced for safety by a qualified electrical contractor.
GFCI's save lives!
6.5 (Item 1)
|
6.6 |
OPERATION OF AFCI (ARCH FAULT CIRCUIT INTERRUPTERS)
Comments and observations: Not Present |
Information/Disclosure - Non Arch Fault Circuit Interrupts , SAFETY - This home was built before
AFCI protection was required in 1999 and therefore is missing AFCI protection in bedrooms. AFCI's
protect against electrical arcs, sparking and fires.. Recommend consider upgrading to AFCI
protection.
“Older homes are statistically more vulnerable to electrical fires. Extra protection for older homes can be accomplished by the gradual replacement of non-AFCI receptacles with AFCI-protected receptacles.” AFCI's prevent fires. Click here for more information on AFCI's |
6.7 |
SMOKE and CARBON MONOXIDE DETECTORS
Comments and observations: Inspected |
(1) Testing - Smoke and carbon monoxide detectors are tested as a courtesy only and not part of our
standards of practice. They may work today and not tomorrow, especially the battery operated ones.
It is the responsibility of the home owner to maintain these safety devices and test at least monthly.
Safety advisory - Install modern smoke and Carbon monoxide detectors as needed and where needed for and test monthly. Older detectors should be updated. Change the batteries annually. These devices save lives. Read more about smoke detectors at US consumer safety products commission. and at National Fire Protection Association. The two most commonly recognized smoke detection technologies are ionization smoke detection and photoelectric smoke detection. Ionization smoke detection is generally more responsive to flaming fires. How they work: Ionization-type smoke alarms have a small amount of radioactive material between two electrically charged plates, which ionizes the air and causes current to flow between the plates. When smoke enters the chamber, it disrupts the flow of ions, thus reducing the flow of current and activating the alarm. Photoelectric smoke detection is generally more responsive to fires that begin with a long period of smoldering (called “smoldering fires”). |
|
(2) Safety, Repair - One or more installed smoke detectors are outdated, unreliable (Item 1). Have repaired
or replaced as needed by a professional. Test again during final walk-thru inspection then continue to test
monthly. Properly working smoke detectors save lives.
6.7 (Item 1)
|
AC - The inspector shall: A. open readily openable access panels. B. inspect: 1. central and permanently installed cooling equipment. 2. distribution systems. C. describe: 1. energy source(s). 2. cooling systems.9.2 The inspector is NOT required to: A. inspect electric air cleaning and sanitizing devices. B. determine cooling supply adequacy and distribution balance. C. inspect cooling units that are not permanently installed or that are installed in windows. D. inspect cooling systems using ground-source, water-source, solar, and renewable energy technologies.
FIREPLACES AND FUEL-BURNING APPLIANCES - The inspector shall: A. inspect: 1. fuel-burning fireplaces, stoves, and fireplace inserts. 2. fuel-burning accessories installed in fireplaces. 3. chimneys and vent systems.B. describe systems and components listed in 12.1.A.1 and .2. The inspector is NOT required to: A. inspect: 1. interiors of vent systems, flues, and chimneys that are not readily accessible. 2. fire screens and doors. 3. seals and gaskets. 4. automatic fuel feed devices. 5. mantles and fireplace surrounds. 6. combustion air components and to determine their adequacy. 7. heat distribution assists (gravity fed and fan assisted). 8. fuel-burning fireplaces and appliances located outside the inspected structures. B. determine draft characteristics. C. move fireplace inserts and stoves or firebox contents.
~ Overview Photos ~
GENERAL HEAT SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
HEAT SYSTEM - SERVICE LIFE REMAINING::
30% - 50% (Fair - No immediate cost concerns ouside of maintenance/repairs) |
Heat Type:
Natural Gas, Forced air furnace Combination of systems Gas pack system |
Heat system(s) performance:
Satisfactory |
Heat system(s) capacity:
Satisfactory |
Heat System Energy Source:
Natural gas |
Number of Central Heat Systems:
Two |
GENERAL AC/ HP SYSTEM CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
HEAT PUMP / AC - SERVICE LIFE REMAINING::
30% - 50% (Fair - No immediate cost concerns ouside of maintenance/repairs) |
Cooling Equipment Type:
Combination of systems Traditional central AC, split system Central AC gas packs |
AC/Heat Pump system(s) performance:
Satisfactory |
AC/Heat Pump system(s) capacity:
marginal but acceptable |
Number of Central AC / HP systems:
Two |
Number of conditioned zones in the house/building:
2 |
Ductwork:
insulated flex duct |
Filter Type:
Disposable clogged, replacement needed |
Types of Fireplaces:
Vented gas logs |
Number of operable fireplaces:
One |
7.0 |
HEATING, FURNACE EQUIPMENT
Comments and observations: Inspected |
(1) Downstairs heat equipment performance - The temperature rise test was performed by taking
temperature readings of the heat supply and return air to determine if it is within factory specifications
(Items 1-2). This furnace specifies a temperature rise of 35 - 65 degrees F. The actual temperature rise
reading is 55 degrees F. This indicates satisfactory performance and the system is functioning as
designed.
7.0 (Item 1)
7.0 (Item 2)
|
|
(2) Heat equipment performance - The temperature rise test was performed by taking temperature
readings of the heat supply and return air to determine if it is within factory specifications (Items 3-4). This
furnace specifies a temperature rise of 40 - 70 degrees F. The actual temperature rise reading is 69
degrees F. This indicates satisfactory performance and the system is functioning as designed.
7.0 (Item 3)
7.0 (Item 4)
|
7.1 |
PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM
Comments and observations: Inspected |
7.2 |
AC COOLING, HEAT PUMP AND AIR HANDLER EQUIPMENT
Comments and observations: Inspected |
(1) Downstairs equipment performance - The ambient air test was performed by using thermometers on
the air handler of Air conditioner to determine if the difference in temperatures of the supply and return air
are between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply
air temperature on your system read 49 degrees (Item 1), and the return air temperature was 66 degrees
(Item 2). This difference of 17 degrees indicates satisfactory performance and the system is functioning
as designed.
7.2 (Item 1)
7.2 (Item 2)
|
|
(2) Upstairs equipment performance - The ambient air test was performed by using thermometers on the
air handler of Air conditioner to determine if the difference in temperatures of the supply and return air are
between 14 degrees and 22 degrees which indicates that the unit is cooling as intended. The supply air
temperature on your system read 46 degrees (Item 3), and the return air temperature was 66 degrees
(Item 4). This difference of 20 degrees indicates satisfactory performance and the system is functioning
as designed.
7.2 (Item 3)
7.2 (Item 4)
|
|
(3) Deficiency - The insulation sleeve on suction line is not installed in attic (Item 5). Missing insulation on
suction line can cause energy loss and condensation. Recommend maintenance repair as needed.
7.2 (Item 5)
|
7.3 |
PRESENCE OF INSTALLED AC/HP SOURCE AIR IN EACH ROOM
Comments and observations: Inspected |
7.4 |
NORMAL OPERATING CONTROLS
Comments and observations: Inspected |
7.5 |
DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments and observations: Inspected |
(1) Inspection Limitation - The internal parts of air ducts are concealed and not fully visible for inspection. Dirty ducts can degrade system performance and indoor air quality. Ducts can contain, mold, mildew, rodent feces, or allergens which can diminish indoor air quality and cause problems for individuals with allergies. Unless the ductwork is new, professional cleaning and disinfecting is recommended when purchasing a home and should be done by a licensed and NADCA certified duct cleaning contractor. | |
(2) Defect - The duct shroud cover between the exterior wall and the HVAC unit has failed caulk seals is is
separated and is heavily rusted This condition can allow harmful water intrusion or damaging vermin entry.
(Items 1 and 2) The shroud be repaired and completely sealed. It is recommend that this be evaluated
and repaired as needed by a qualified HVAC repair contractor.
Implications: Water intrusion, Vermin damage. Time frame: Immediate Cost: Low 7.5 (Item 1)
7.5 (Item 2)
|
|
(3) Maintenance - The disposable return filter is clogged and is dirty (Item 3). The filter needs to be
replaced. Note: a restricted return air filter can cause reduced air flow, reduced efficiency and damage to
equipment.
7.5 (Item 3)
|
|
(4) Dirty HVAC ducts - The ductwork appears to need professional cleaning (Items 4-5). Visible areas of the
duct/air movement system show dust and dirt buildup which can degrade system performance and indoor
air quality. Dirty ducts can contain allergens which can diminish indoor air quality and cause problems for
individuals with allergies. Some duct materials such as duct board can not be cleaned and may require
replacement. It is recommended that you seek further evaluation and remedy from a licensed and
NADCA certified duct cleaning and repair contractor.
7.5 (Item 4)
7.5 (Item 5)
|
7.6 |
CHIMNEYS, FLUES AND VENTS (for fireplaces, water heaters or heat systems)
Comments and observations: Inspected |
Maintenance / Repair - The metal flashing cap at the top of framed wood chimney is rusting and
deteriorating (Item 1). Recommend preventative maintenance and repairs before it fails and leaks.
Implications: Water damage to chimney. Time frame: Normal maintenance Cost: Low 7.6 (Item 1)
|
7.7 |
SOLID FUEL HEATING DEVICES (Fireplaces, Woodstove)
Comments and observations: Inspected |
7.8 |
GAS/LP FIRELOGS AND FIREPLACES
Comments and observations: Inspected |
(1) Observation - Natural gas fireplace responded to testing at the time of the inspection. (Item 1)
7.8 (Item 1)
|
|
(2) Defect, safety - The fireplace has been fitted with gas logs but the flue damper clamp is missing (Items
2-3). The damper clamp is a safety device that is intended to prevent fully closing of the flue damper in
which case harmful or deadly combustion by-products may enter the home. Recommend having a damper
clamp installed for safety.
7.8 (Item 2)
7.8 (Item 3)
|
~ Overview Photos ~
GENERAL INSULATION CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
Attic insulation:
Loose or blown in cellulose approx. R-13 |
Wall insulation:
concealed, not visible, not inspected |
Floor System Insulation:
Batts Fiberglass R-11 |
Bathroom steam vents:
Fan Window |
Dryer Power Source:
220 Electric |
Dryer duct (built in):
Metal |
8.0 |
INSULATION IN ATTIC / CEILING
Comments and observations: Inspected |
(1) Deficiency - The insulation at the knee-wall door is inadequate or missing and will permit significant loss
of conditioned air and reduced HVAC efficiency (Items 1-2). While this is typical for older homes, new
construction and remodeled homes require the insulation at these access points be at least equal to the
surrounding area. For example the wall would be R13 and ceiling R38 resistance to heat loss/gain.
Recommend further evaluation and improvements/repairs be completed by an insulation contractor.
Implication: Increased heating and cooling cost. Time frame: Discretionary. Cost: Low 8.0 (Item 1)
8.0 (Item 2)
|
|
(2) Defect - Observed fallen and matted insulation in the knee wall attic (Item 3). Seems to be due to vermin
intrusion, (most likely a squirrel) trying to make a nest in the insulation (Item 4). Recommend repairing
the vermin entry point first, then repairing the insulation. Repairs to be completed by a qualified
contractor.
8.0 (Item 3)
8.0 (Item 4)
|
8.1 |
WALL INSULATION (if visible)
Comments and observations: Not Inspected |
8.2 |
INSULATION UNDER FLOOR SYSTEM
Comments and observations: Inspected |
8.3 |
VENTING SYSTEMS (Kitchens, baths and laundry)
Comments and observations: Inspected |
(1) SAFETY ADVISORY- Dryer ducts should be cleaned and inspected annually for proper performance.
Dryer ducts are susceptible to clogging and blockage due to lint and moisture build up. Restricted
dryer vents will not only reduce drying efficiency, but worse they can overheat and cause fires.
If your dryer used a vinyl or foil flex duct connector you should dispose of it and replace with flexible aluminum duct. Aluminum duct is the most efficient type, safest type to reduce fire hazards and the only type recommended by dryer manufactures and by most municipal building codes. Dryer vent installation guidelines See more about dryer duct safety here. |
|
(2) Defect, Safety - Dryer duct is full of lint and air flow is restricted which will greatly reduce dryer efficiency
and can also cause overheating and fire (Item 1). Recommend professional cleaning, repair and testing to
ensure safe and proper function.
8.3 (Item 1)
|
|
(3) Defect, Safety - Improper clothes dryer duct materials. (Item 2) Permanent dryer ducts must be made of
rigid, smooth-wall materials and secured with approved straps or hangers and vented to the exterior
atmosphere with a reverse airflow damper shroud (Item 3). Flexible or semi-flexible dryer ducts are not
permitted for use in permanent or non-serviceable areas. They will clog and can overheat causing fires.
They can deteriorate and introduce damaging moisture into structure. At best they will significantly reduce
dryer efficiency and performance. Recommend proper and professional repairs be completed by a
qualified duct cleaning and installation contractor.
8.3 (Item 2)
8.3 (Item 3)
|
|
(4) Defect - Improper location of dryer vent duct (Item 4). It is at grade level not allowing for proper ventilation
and is subject to exterior debris to clog and block the vent. Recommend repairs be completed by a
qualified contractor.
8.3 (Item 4)
|
~ Overview Photos ~
GENERAL APPLIANCE CONDITION / RATING:
Good (No significant concerns, functioning as designed) |
GARBAGE DISPOSAL:
Not Functional |
DISHWASHER:
Functional |
RANGE/OVEN/STOVE/COOK TOP:
Functional |
MICROWAVE OVEN (built in):
Functional |
STOVE EXHAUST / RANGE HOOD:
Functional Not vented to exterior. Recirculate type. |
INDOOR DOWN DRAFT GRILL:
None installed |
TRASH COMPACTOR:
None installed |
9.0 |
DISHWASHER
Comments and observations: Inspected |
9.1 |
RANGES/OVENS/COOKTOPS
Comments and observations: Inspected |
9.2 |
RANGE HOOD
Comments and observations: Inspected |
9.3 |
GARBAGE DISPOSAL UNIT
Comments and observations: Inspected |
Defect - Garbage disposal did not respond to testing at the time of the inspection (Item 1). Unable to
determine why it did not function. Recommend further evaluation and repairs to be completed by qualified
plumbing contractor.
9.3 (Item 1)
|
9.4 |
MICROWAVE COOKING EQUIPMENT
Comments and observations: Inspected |